MegaTherm®

High Performance Gas Fired Commercial Pool Heaters

DIMENSIONAL AND SIzINg DAtA

For Indoor Pools Model I

1. Calculate the surface area of the pool in square feet.
2. Refer to the selection chart for either an indoor or outdoor heater.
3. Find the closest square footage in the 10° F (6° C) Temperature Difference column, and the heater models which correspond to it. For normal conditions,
Pentair recommends using the 10° F Temperature Difference columns; this will provide a temperature increase of approximately 6° F per 24 hour period.
10° F 6° C 15° F 8° C 20° F 11° C 25° F 14° C 30° F 17° C 35° F 19° C 40° F 22° C 45° F 25° C 50° F 28° C
Model Surface Area of Pools (Sq. Ft.)
500 I 3900 362 2600 242 1950 181 1560 145 1300 121 1115 104 975 91 870 81 780 72
600 I 4680 435 3120 290 2340 217 1870 174 1560 145 1340 124 1170 109 1040 97 935 87
715 I 5580 518 3720 346 2790 259 2230 207 1860 173 1595 148 1395 130 1240 115 1115 104
850 I 6630 616 4420 411 3315 308 2650 246 2210 205 1895 176 1660 154 1475 137 1325 123
1010 I 7880 732 5250 488 3940 366 3150 293 2625 244 2259 210 1970 183 1750 163 1575 146
1200 I 9360 870 6240 580 4680 435 3745 348 3120 290 2675 249 2340 217 2080 193 1870 174
1430 I 11155 1036 7435 691 5580 518 4460 414 3720 346 3190 296 2790 259 2480 230 2230 207
1670 I 13025 1210 8685 807 6515 605 5210 484 4340 403 3720 346 3260 303 2895 269 2605 242
1825 I 14235 1322 9490 882 7120 661 5695 528 4745 441 4070 378 3560 331 3165 294 2850 265
2000 I 16400 1524 10935 1016 8200 819 6560 609 5465 508 4685 435 4100 381 3645 339 3280 305
2450 I 20090 1866 13395 1244 10045 933 8035 746 6695 622 5740 533 5025 467 4465 415 4020 373
3050 I 25010 2323 16675 1549 12505 1162 10000 929 8335 744 7145 664 6255 581 5560 517 5000 465
3500 I 28700 2666 19135 1778 14350 1333 11480 1066 9565 889 8200 764 7175 667 6380 593 5740 533
4050 I 33210 3085 22140 2057 16605 1543 13285 1234 11070 1028 9490 882 8300 771 7380 686 6640 617
4500 I 36900 3428 24600 2285 18450 1714 14760 1371 12300 1143 10545 980 9225 857 8200 762 7380 686
5000 I 41000 3809 27335 2539 20500 1904 16400 1524 13665 1269 11715 1088 10250 952 9110 846 8200 762
temperature Difference
Indoor
Sizes 500–1825
Indoor
Sizes 2000 –5000
Dimensional Data
Indoor Input1 Output1
-
inches NPt
-
inches Dimensions2 - inches cm Weight3
Size MBtU/h kw MBtU/h kw Nat LP NPt A B C V lbs. kg
500 I 500 147 405 119 1 34 2
12 3334 86 4514 115 2334 60 10 25 808 367
600 I 600 176 486 143 1 34 2
12 3834 98 5014 128 2234 58 12 30 819 372
715 I 715 210 579 170 1 34 2
12 4414 112 5534 142 2234 58 12 30 873 396
850 I 850 249 689 202 1 34 2
12 5034 129 6214 158 2134 55 14 36 945 429
1010 I 1010 296 818 240 1
14 1 212 58 147 6912 177 2034 53 16 41 1041 473
1200 I 1200 352 972 285 1
14 1 212 6614 168 7734 197 2034 53 16 41 1199 544
1430 I 1430 419 1158 339 1
14 1
14 2
12 76 193 8712 222 1934 50 18 46 1280 581
1670 I 1670 489 1353 396 1
12 1
14 2
12 8512 217 97 246 1934 50 18 46 1445 656
1825 I 1825 535 1478 433 1
12 1
14 2
12 9212 235 10334 264 1934 50 18 46 1570 713
2000 I 2000 586 1639 480 1
12 1
14 4 5512 141 73 185 2412 62 22 56 1950 885
2450 I 2450 718 2009 589 1
12 1
12 4 6512 166 83 211 2412 62 24 61 2100 913
3050 I 3050 894 2501 733 2 112 4 78 198 9512 243 2412 62 26 66 2250 1022
3500 I 3500 1025 2870 841 2 112 4 88 224 10512 268 2412 62 28 71 2510 1140
4050 I 4050 1186 3321 973 2 2 4 10012 255 118 300 2412 62 30 76 2750 1249
4500 I 4500 1318 3690 1081 2
12 2 4 11012 281 128 325 2412 62 32 81 2900 1317
5000 I 5000 1465 4100 1201 2
12 2 4 123 312 14012 357 2412 62 34 86 3200 1453
gas Conn. Size2
Water Conn. Size2
NOTES: 1. Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude.
2. Dimensions are nominal.
3. Integral pump included on sizes 500-1825.
Shipping