Before Operation:

Read the following instructions carefully. Reasonable care and safe methods should be practiced. Check local codes and requirements before installation.

Attention:

This manual contains important information for the safe use of this product. Read this manual completely before using this product and refer to it often for continued safe product use.

DO NOT THROW AWAY OR LOSE THIS MANUAL. Keep it in a safe place so that you may refer to it often.

Warning:

Before handling these pumps and controls, always disconnect the power first. Do not smoke or use sparkable electrical devices or flames in a septic (gaseous) or possible septic sump.

FG-A1 and Pump Warning

CAUTION AND WARNING

Important Safety

Instructions

Rules for Safe Installation and Operation

1.READ THESE RULES AND INSTRUCTIONS CAREFULLY. Failure to follow them could cause serious bodily injury and/or property damage.

2.Check local plumbing and electrical codes before installing. You must comply with those rules.

3.Battery box must be kept in a cool, dry, well ventilated area.

4.Battery must not be exposed to any sparks or flames. An explosion or fire could result.

5.Battery acid is very corrosive; avoid spilling on skin or clothing. Eye protection must be worn when handling the battery.

6.Battery Selection and Maintenance

Use a new 12 volt, fully charged battery with top terminals. For maximum performance and battery life, a deep cycle (marine, group 24, min. 105 AH) battery should be used.

The electrolyte level should be checked monthly and filled as required. Automotive batteries may be used but a slight decrease in performance and battery life will result.

Group 24 batteries will fit into the battery box with maximum battery dimensions of 12" long x 6-1/2" wide x 9" high to the top of the terminals.

Replace the battery if the back-up pump operated for an extended period of time and the battery is severely discharged. It is also recommended that the battery be replaced every three years even if the system is not used.

7.When service is required, proceed carefully:

Disconnect the power at the main electrical service box by turning the circuit breaker off or by removing the fuse.

Disconnect the battery charger from the wall after the power is disconnected.

DO NOT lift the pump by the cord.

8.To be used only as a back-up sump pump in residential waste water applications. DO NOT run the pump dry.