Section IV. Operation

26

 

 

SET UP

The MiniMax NT Heater comes from the factory preset with a pool temperature setting of 78° F. and a preset spa temperature of 100° F., and in the off mode setting. Once the power is turned on, the DDTC board will do a self diagnostic internal check, during this time the display will first read “888”, then the display will switch to three dashes “- - -“, this process takes approximately ten (10) seconds. The DDTC will then illuminate the “Power” LED and “Off” LED, see Figure 27.

1.Turn on the power to the heater; the switch is on the bottom of the electrical junction box located inter- nally on the right side of the cabinet. The DDTC will now go through the self-diagnostic’s test as stated above.

2.Turn on the circulating system pump and make sure that adequate water is being delivered to the heater, The “PRESSURE SW” LED will now illuminate.

3.If you are using the heater with a remote control system, open the right door of the heater to access the rear portion of the DDTC. Locate the three terminals marked “Pool” (J5), “Spa” (J6) and “Com” (J8). If the remote system is a three-wire remote unit, connect the pool lead to the “pool” terminal J5, connect the spa lead to the “spa” J6 terminal and connect the common wire to the “com” terminal J8. If the remote system is a two-wire remote, the remote system will be used to turn the heater on for a selected body of water, Pool or Spa, select which application you are working with and connect one wire to the common terminal J8 and the other wire to either “Pool J5” or “Spa J6”. Close and latch the door.

LED INDICATORS

There are nine lights that can be seen from the front of the control panel, (five are system indicators and four are mode indicators), which helps you understand the operation of the heater, see Figure 26. If something should go wrong, the lights will aid in troubleshooting the problem. An additional four lights can be seen after opening the control panel. These four lights are diagnostic indicators for the service technician to troubleshoot the system.

On the right front of the DDTC board there are four Buttons and corresponding LED lights, see Figure 26. Using the buttons allows you to select one of the four modes and the lights indicate which operational mode that the heater is in, Off, Spa mode, Pool mode or Remote mode. If the heater is not connected to a remote system then the remote mode will not be used.

The following are descriptions of the five system indicators:

• POWER

The light is on at all times, in any switch position, indicating 24 VAC power is being supplied to the control circuit. If it fails to light, no other light will be on. Possible causes are:

1.External power to the heater is disconnected; check service panel circuit breaker or fuses;

2.Transformer has failed.

• PRESSURE SW (WATER PRESSURE SWITCH)

This light is on when Spa/Pool Selector switch is on, indicates the circulating pump is running properly. If pressure light fails to light, the pump may have lost its prime or water flow may be restricted by an inadvertently closed valve or clogged filter or pump basket. If you have determined that there is no water flow restriction to the heater, you should call a qualified technician.

• THERMOSTAT

This light is on when the thermostat contacts close, signaled by the water temperature falling below the set-point, calling for the heater to fire to maintain the desired water temperature.

P/N 472235

Rev. E 4-15-05

Page 26
Image 26
Pentair NT Series installation manual Set Up

NT Series specifications

Pentair is a renowned name in the realm of water filtration and fluid management solutions, and the NT Series stands out as a key player in their extensive product lineup. Engineered for optimal performance and reliability, the NT Series showcases innovative features and technologies that cater to various water treatment needs.

One of the defining characteristics of the Pentair NT Series is its exceptional filtration capabilities. These filters are designed to effectively remove sediments, chlorine taste and odor, and other contaminants, ensuring clean and safe drinking water. With a multi-stage filtration process, the NT Series utilizes advanced materials and technologies that enhance filtration efficiency and longevity.

The NT Series is equipped with advanced filter media that can capture particles as small as 0.5 microns. This level of filtration is essential for households and commercial applications, where water quality is paramount. The filters are also designed for easy replacement, ensuring minimal downtime and ease of maintenance for users.

Another prominent feature of the NT Series is its compact design, making it suitable for various installation spaces. The filters are engineered to maximize flow rate while maintaining high filtration efficiency, ensuring that users do not experience reduced water pressure. This balance of performance and design is integral, especially in demanding applications.

Moreover, the NT Series incorporates innovative technology to monitor filter life and performance. Several models come with built-in sensors that provide real-time data on filter conditions, allowing users to know when it's time for a replacement. This proactive approach to maintenance enhances user experience and ensures continued access to high-quality water.

The materials used in the NT Series are also noteworthy. Constructed from durable, corrosion-resistant components, these filters are designed to withstand harsh operating conditions while maintaining peak performance over time. This enhances the overall lifespan of the product, providing users with a reliable and long-lasting solution for their water filtration needs.

In summary, the Pentair NT Series represents a blend of advanced filtration technology, user-friendly design, and durable construction. With its ability to remove various contaminants, easy maintenance features, and compact design, the NT Series caters to residential and commercial users alike. Investing in the NT Series ensures access to clean, great-tasting water while enjoying the benefits of reliable and efficient filtration technology.