Section III. Installation

18

 

 

OUTDOOR INSTALLATION (Outdoor Shelter Installation in Canada, see page 15)

For outdoor installation with an exhaust grill, the heater must be placed in a suitable area on a level, noncombustible surface. Do not install the heater under an overhang with clearances less than 3 feet from the top of the heater. The area under an overhang must be open on three sides. Do NOT, under any circumstances, install the heater under ANY deck.

IMPORTANT!

In an outdoor installation it is important to ensure water is diverted from overhanging eves with a proper gutter/drainage system. The heater must be set on a level foundation for proper drainage.

Under certain conditions, “heavy rains or unusually high winds”, it may be necessary to install an outdoors vent. In this situation, use Outdoor Vent Kit, P/N 460424, (see below).

This unit shall not be operated outdoors at temperatures below -20oF.

OUTDOOR INSTALLATION

VENTING GUIDELINES

4' 3'

SIDE VIEW

4'

 

4 ft.

4'

 

Window

 

4 ft.

Exhaust Grill

 

(Vent)

Building

 

Heater

(side view)

 

Property Line

 

 

 

 

 

 

codes.

 

 

 

building

ents

Force

 

 

local

requirem

 

 

setback

 

 

Air Inlet

Check

 

 

 

 

 

 

 

 

 

for

 

 

 

 

Vent Termination:

Must be at least 3 ft. above any forced air inlet located within a 10 ft. radius.

Must be located 4 feet away from the building wall

Figure 13.openings, and at the following distances away from any door, window, or gravity air inlet:

4 ft. below,

4 ft. horizontally

OUTDOOR VENT KIT

1.Remove the six (6) retaining screws from the old exhaust grill and discard the screws, gasket, and exhaust grill as shown in Figure 14.

2.Install the Outdoor Vent Kit, (P/N 460424), as shown in Figure 15. Make sure the holes in the gasket, metal flange of the main vent assembly, and heater cover are aligned before securing into place using the six (6) screws provided in the Outdoor Vent Kit.

 

 

EXHAUST GRILL

METAL FLANGE

 

 

SCREWS (6)

 

 

SCREWS (6)

 

 

 

 

GASKET

 

GASKET

 

 

 

Figure 14.

 

 

Figure 15.

CAUTION

If installing the heater next to or near an air conditioning unit or a heat pump, allow a minimum of 36 in. between the air conditioning unit and the heater.

P/N 472235

Rev. E 4-15-05

Page 18
Image 18
Pentair NT Series installation manual Outdoor Vent KIT, Outdoor Installation Venting Guidelines Side View

NT Series specifications

Pentair is a renowned name in the realm of water filtration and fluid management solutions, and the NT Series stands out as a key player in their extensive product lineup. Engineered for optimal performance and reliability, the NT Series showcases innovative features and technologies that cater to various water treatment needs.

One of the defining characteristics of the Pentair NT Series is its exceptional filtration capabilities. These filters are designed to effectively remove sediments, chlorine taste and odor, and other contaminants, ensuring clean and safe drinking water. With a multi-stage filtration process, the NT Series utilizes advanced materials and technologies that enhance filtration efficiency and longevity.

The NT Series is equipped with advanced filter media that can capture particles as small as 0.5 microns. This level of filtration is essential for households and commercial applications, where water quality is paramount. The filters are also designed for easy replacement, ensuring minimal downtime and ease of maintenance for users.

Another prominent feature of the NT Series is its compact design, making it suitable for various installation spaces. The filters are engineered to maximize flow rate while maintaining high filtration efficiency, ensuring that users do not experience reduced water pressure. This balance of performance and design is integral, especially in demanding applications.

Moreover, the NT Series incorporates innovative technology to monitor filter life and performance. Several models come with built-in sensors that provide real-time data on filter conditions, allowing users to know when it's time for a replacement. This proactive approach to maintenance enhances user experience and ensures continued access to high-quality water.

The materials used in the NT Series are also noteworthy. Constructed from durable, corrosion-resistant components, these filters are designed to withstand harsh operating conditions while maintaining peak performance over time. This enhances the overall lifespan of the product, providing users with a reliable and long-lasting solution for their water filtration needs.

In summary, the Pentair NT Series represents a blend of advanced filtration technology, user-friendly design, and durable construction. With its ability to remove various contaminants, easy maintenance features, and compact design, the NT Series caters to residential and commercial users alike. Investing in the NT Series ensures access to clean, great-tasting water while enjoying the benefits of reliable and efficient filtration technology.