CHEMICAL CLEANING

Hazardous pressure. Can cause severe injury or major property damage from tank blow up.

Release all pressure and read instructions before working on filter.

collars may need to be cleaned before reassembly.

10. Follow filter assembly procedure, Page 8.

To avoid severe injury or major property damage, exactly follow instructions under “Assembly” (Page 8)!

11.If unit is returning to service, see “Initial Startup”, Page 7.

12.If cleaning is part of seasonal shutdown, see “Winterizing”, Page 12.

CHEMICAL CLEANING

PROCEDURE

Before Disassembling Filter:

1. STOP PUMP.

2.OPEN air release valve.

3.WAIT until all pressure is released from filter tank and system before loosening clamps.

NOTICE: Do not expose element cloth to direct sunlight for long periods. Direct sunlight will cause the cloth to deteriorate.

NOTICE:To avoid damaging fabric, do not allow filter element to rub on con- crete or any abrasive surface during cleaning.

NOTICE: Clean filter manually before doing any chemical cleaning.

Filter Disassembly:

To avoid severe injury or major property damage exactly follow instructions under “Disassembly” (Page 8)!

1.Disassemble and inspect element grid assemblies for tears and worn areas. Replace as needed.

2.Rinse each grid thoroughly with water.

3.Wash each grid with a mild soap solution or commercial filter cleaner. If necessary, soak element grids in filter cleanser to remove buildup of oils, etc.

4.Rinse thoroughly to remove all soap film.

5.If filter elements do not come clean after soaking, have your pool profes- sional acid clean them.

Filter Disassembly:Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Risk of burns, explosions, and environmental damage. Only trained professionals should attempt to acid clean filter elements.

7.Reassemble element grids.

8.Inspect inside of filter tank and remove any debris which remains after backwashing.

9.Thoroughly clean air relief filter screen (Key No. 2, Page 15) on top of manifold. Be sure to remove all debris from screen. Replace filter screen if damaged.

10.Follow filter assembly procedure, Page 8.

To avoid severe injury or major property damage, follow instructions under “Assembly” (Page 8)!

11. If unit is returning to service, see “Initial Startup”, Page 7.