7

Section 4

Maintenance

To Backwash (Clean) Filter

WARNING — To prevent equipment damage and possible bodily injury and/or property damage, always turn the pump off before changing the valve positions.

1.Pressure backwashing is accomplished in four easy steps:

a.Turn pump off.

b.Rotate handle of rotary valve 90o as shown in Figure 2.

STAND CLEAR OF THE FILTER.

c.Turn pump on.

d.Backwash for approximately two minutes or until effluent appears clean. When backwashing is complete, turn pump off, rotate handle back to filter position and you are ready for filter operation again. Precoat filter with D.E. as shown on

page 4, Table 1.

Figure 2.

 

How to Clean the Separation Tank, performed after each backwash operation. (If installed or if applicable.)

The purpose of the separation tank is to collect the spent diatomaceous earth during backwashing (cleaning) of the filter. It must be cleaned after each backwash to prevent any clogging problems. It is recommended that this procedure be repeated to ensure complete backwashing of the filter. One backwashing may not be sufficient.

1.Open valve “C” and valve “D”* to drain separation tank. While the tank drains, the filter can be pre-coated and restored to the filter cycle. Be sure valve “B” is closed. See Figure 3.

WARNING — *Valve "D" is the air relief valve. It is important that this valve be opened before proceeding

further. The tank is pressurized and is dangerous if the air is not vented prior to removing the lid clamp. Failure to open the air relief valve could cause the lid to separate resulting is serious bodily injury and/or property damage.

2.To remove the clamping ring, partially unscrew the adjustment knob and release the head of the T-bolt from the slotted bracket.

3.Remove tank lid with screwdriver or with a tool available from the manufacturer, see page 9, Figure 5. Avoid cutting rubber O-ring.

4.When water has drained from bag, remove bag from tank by grasping the handles of the bag with both hands; pushingdownwithonehand;pullingupwiththeotherandliftingbagout.

5.Turn bag inside out and empty contents is a waste container. Rinse bag with garden hose.

6.Install bag in tank with the rim of the bag immediately below the tank inlet opening, then push downon therimopposite the inlet opening until the rim is level.

7.Remove rubber O-ring and clean both O-ring and channel. Lubricate O-ring with a non-water soluble grease or silicone lubricant and replace O-ring in channel.

8.Clean the inside surface of the tank lid where it seals against the O-ring. Place lid on tank; push down on lid to seat in-place.

Figure 3.

9.Replace the clamping ring. Engage the head of the T-bolt into the slotted bracket and tighten the adjustment knob. Hand tighten only.

SM/SMBW 2000 Series™ Filter Installation and User’s Guide

Page 13
Image 13
Pentair SM/SMBW 2000 important safety instructions Section Maintenance, To Backwash Clean Filter

SM/SMBW 2000 specifications

The Pentair SM/SMBW 2000 series represents a significant advancement in water treatment and filtration technology, specifically designed for both commercial and industrial applications. This system is engineered to deliver high-quality water while ensuring operational efficiency and reliability.

One of the standout features of the Pentair SM/SMBW 2000 is its versatile design, which accommodates a wide range of applications including process water, cooling water, and waste reduction, making it ideal for various industries. The system integrates advanced filtration technology, ensuring the removal of contaminants, particulates, and other unwanted substances to produce clean, high-purity water.

The system is equipped with state-of-the-art sensor technology that allows for real-time monitoring and management of operational parameters. This feature not only enhances the system’s performance but also enables users to respond swiftly to any deviations, ensuring consistent water quality. The modular design of the SM/SMBW 2000 also contributes to its user-friendly nature, allowing for easy maintenance, upgrades, and adaptability to changing water quality needs.

In terms of energy efficiency, the Pentair SM/SMBW 2000 is designed to minimize energy consumption without compromising on performance. Its advanced control systems optimize pump operation and filtration processes, which results in lower operational costs and reduced environmental impact.

Moreover, the SM/SMBW series is built with robust materials that are resistant to corrosion and wear, ensuring longevity in demanding environments. This characteristic is essential for industries where equipment reliability is critical.

The SM/SMBW 2000 systems also feature an intelligent automation system. This smart technology not only enhances operational efficiency but also provides valuable insights into system performance and water quality through comprehensive data reporting. Users can adjust settings remotely, leading to increased convenience and operational efficiency.

In summary, the Pentair SM/SMBW 2000 series combines advanced filtration technology, energy efficiency, and intelligent monitoring to provide superior water treatment solutions for various commercial and industrial applications. Its reliability, ease of use, and adaptability make it a noteworthy choice for those seeking to optimize water quality and operational performance in their facilities. As water quality standards continue to evolve, the Pentair SM/SMBW 2000 stands ready to meet and exceed the challenges faced by today's water treatment demands.