Wiring

Wiring

The IntelliPro VS-3050should be wired line side, i.e. directly to a 220V to 240V circuit breaker with a minimum 20 amp rating or other source of “line” voltage supply. IntelliPro is designed for 230V applications only. 115V circuits will not operate and could cause damage to the pump. If IntelliPro is connected to a mechanical time clock or other mechanical on/off circuitry, e.g. household light switch with a 20 amp minimum rating, then “load” side voltage is acceptable.

Use of a UL listed 3⁄4 inch FIP LB (line box) is recommended for pump side electrical connection.

When wiring the IntelliPro to a mechanical timer or on/off switch, the included RS485 Data Communication Cable Part #340122 will not be necessary.

Plumbing

When plumbing the IntelliPro VS-3050, a 4 inch gap should be left between the top of the pump drive and any obstructions, plumbing or wiring that may hinder an authorized warranty technician in the drive removal and replacement procedure.

IntelliProVS-3050Quick-Start Guide