Applications
2.30 — IOLINK-520 & IOLINK-PRO Installation & Applications Guide
The DLCI number defined here is the Data Link Connection Identifier
value provided by your frame relay service provider. This value must be
set if auto-learning is disabled.
Each Remote Site PVC must be defined to exist on one of the two physical WAN links
available on this IOLINK router.
Primary Link
Location: Main
! Configuration
! Connections up
! Remote Site Set-up
! Edit Remote Site
! Connection Set-up
! Primary Link
The Primary Link value defines to which of the two physical WAN links
that this PVC will be assigned. This value must be set.
Two other values must be set before the remote site profiles are fully configured, the CIR
and EIR. The Committed Information Rate (CIR) option specifies the data rate that the
Frame Relay service has guaranteed to provide. The Excess Information Rate (EIR)
option specifies the data rate that the Frame Relay service indicates may be available for
this PVC.
CIR
Location: Main
! Configuration
! Connections up
! Remote Site Set-up
! Edit Remote Site
! Connection Set-up
! CIR
The CIR value specifies the guaranteed data rate for this PVC. This
value must be set to the same as the value provided by the Frame Relay
network provider. The value of 0 indicates that there is no commitment
on the data rate.
Configuration: When changing the CIR option for this PVC, the PVC must be disabled and
Note then enabled before the new value will take effect.
"
""
"
"
""
"