Applications
IOLINK-520 & IOLINK-PRO Installation & Applications Guide — 2.31
EIR
Location: Main
! Configuration
! Connections up
! Remote Site Set-up
! Edit Remote Site
! Connection Set-up
! EIR
The EIR value specifies the indicated data rate that may be available for this
PVC. This value must be set to the same as the value provided by the
Frame Relay network provider. When EIR = 0, no excess burst data is
allowed to be transmitted. If EIR is non-zero, bursting is allowed. The only
restriction is that CIR + EIR > 0.
Configuration: When changing the EIR option for this PVC, the PVC must be disabled and
Note then enabled before the new value will take effect.
The Bridge, IP, IPX, and Compression settings may now be configured within the Bridge,
Parameters, IP Parameters, IPX Parameters, and CCP Parameters menus (note:
compression over frame relay is only available if PPP encapsulation is enabled).
If either the Bridge portion or the IP or IPX router portion of the connection is not
required, the appropriate Connection Protocol setting must be disabled within the
appropriate sub-menu. For example; if an IPX only connection is to be established, the
Bridging and IP parameters must be disabled so that the IOLINK router does not negotiate
the Bridge or IP Connection Protocols on the connection.
Connection Protocol Setting
Location: Main
! Configuration
! Connections up
! Remote Site Set-up
! Edit Remote Site
! Protocol Set-up
! Bridge Parameters
! Bridge enabled
! disabled
! IP Parameters
! IP enabled
! disabled
Disabling a particular connection protocol option will prevent the
IOLINK router from negotiating that Network Connection Protocol.
Leaving all options enabled will result in a Bridge, IP router, and IPX
router connection.
"
""
"
"
""
"