Perlick DP32, DS32 specifications Installation and Tapping - Direct Draw Dispensers Self-Contained

Models: DS32 DP32

1 12
Download 12 pages 5.26 Kb
Page 4
Image 4
Installation and Tapping – Direct Draw Dispensers Self-Contained

Installation and Tapping – Direct Draw Dispensers Self-Contained

Connecting the Keg Coupler

(when Supplied by Perlick)

Place one brown leather washer into black beer line connector hose on hex nut side. Screw connector to stainless steel beverage line on faucet standard. Tighten with a wrench, but do not over tighten.

Make sure lever handle on the keg coupler is in the UP (untapped) position. Place one brown leather washer into wing nut end of black beer line connector hose and thread onto top of keg coupler. Hand tighten.

Place clamp on one end of red air line. Push end over air valve located inside cabinet. Tighten clamp with screwdriver. Turn shut-off valve to OFF (horizontal) position.

Place clamp on the other end of red air line and push over tailpiece on coupler. Tighten clamp with screwdriver.

CAUTION: Do not use keg coupler as a handle to lift keg.

Tapping a Single Valve Keg (Sankey):

Step 1

Single Valve Keg Coupler

Step 3

Step 2

Be sure beer faucet is in closed position.

Align keg lugs with lug openings on bottom of coupler.

Turn clockwise 14 turn. Pull handle out and down. Keg is now tapped.

Open shut-off valve on air divider located inside of the cabinet.

Important: Be sure to close this valve when untapping keg.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Form No. Z2280

4

Page 4
Image 4
Perlick DP32, DS32 Installation and Tapping - Direct Draw Dispensers Self-Contained, Connecting the Keg Coupler