15)Reconnect the suction tube.

16)Hook each separator onto the rail, then pull it hard towards you until it locks into place. See Fig. 38.

17)Replace the slope in its correct position. See Fig. 39.

Separator

Slope

 

Rail

Fig. 38

Fig. 39

18)Discard the sanitizing solution.

19)Mix a new batch of the sanitizing solution and slowly pour it into the water tank.

20)Move the control switch to the "WASH" position.

21)After circulating the sanitizing solution for 15 minutes, move the control switch to the "OFF" position.

22)Disconnect the suction tube. Allow the water tank to drain, then reconnect the suction tube.

23)Repeat steps 19 through 22 one time.

24)Move the control switch to the "ICE" position and allow the icemaker to operate for 2 minutes. This allows the water tank to fill with water.

25)Move the control switch to the "WASH" position.

26)Alow the water to circulate for 5 minutes, then move the control switch to the "OFF" position.

27)Disconnect the suction tube. Allow the water tank to drain, then reconnect the suction tube.

28)Repeat steps 24 through 27 two more times to rinse thoroughly.

29)Clean the storage bin liner, door liner, and door gasket with a neutral cleaner. Rinse thoroughly after cleaning.

30)Move the control switch to the "ICE" position to start the automatic icemaking process.

28

Page 28
Image 28
Perlick H50IMW-AD, H50IMS-ADR, H50IMS-ADL, H50IMS-L, H50IMS-R manual Separator Slope Rail