MAINTENANCE
SEASONAL MAINTENANCE FOR
Winterizing
This process should occur when the daily low temperatures is at or below the temperatures stated below:
Freezer models: 32° F
Refrigerator models: 38° F
Beverage Center: 42° F
Wine Reserve: 45° F
It is best to winterize your unit before the low temperatures listed above.
1.Turn the unit to OFF position by pressing the OFF button on the controller. The controller displays the word “OFF” and, for Signature Series models, turn the master switch located behind the grille off (if the power cord is accessible, unplug the power cord. If not, turn off the circuit breaker to the electrical receptacle the cabinet is plugged into). For
2.Remove all contents from the unit.
3.Remove the front grille.
4.Clean the condenser by using a vacuum cleaner to remove loose debris (leaves, dirt, etc.) that may have accumulated inside the grille.
5.Reinstall the front grille.
6.Clean the interior of the unit using stainless steel cleaner and polish (see page 9).
7.Clean the exterior of the unit using stainless steel cleaner and polish (see page 9).
NOTE: Do not place a cover over the unit. While not required, you may choose to remove the unit from the outdoor location and store indoors.
CAUTION
Operating the unit at temperatures lower than those recommended will void the warranty.
PERLICK RESIDENTIAL INSTALLATION MANUAL
Spring Start-Up
This process should occur after the daily low temperatures is below the temperatures stated below:
Freezer models: 32° F
Refrigerator models: 38° F
Beverage Center: 42° F
Wine Reserve: 45° F
1.Remove the grille.
2.Check the condensing unit to ensure it is clear of loose debris, and clean as necessary with a vacuum cleaner.
3.Reattach front grille to the unit.
4.Clean the interior of the unit using stainless steel cleaner and polish (see page 9).
5.Clean the exterior of the unit using stainless steel cleaner and polish (see page 9).
6.Plug the unit into the electrical receptacle or turn on the circuit breaker.
7.Turn on the master switch located behind the grille if model is Signature Series. Press the OFF button one time to turn the unit on. The controller display will show the actual temperature inside the cabinet.
8.The cooling process will begin to bring the unit to the set temperature. It’s recommended you run the unit for 24 hours to stabilize the operating temperature before using.
DANGER
Never attempt to repair or perform maintenance on the unit until the main electrical power to the unit has been disconnected!
LED REPLACEMENT (SIGNATURE SERIES)
Call your Perlick Factory Authorized Service Center. For the location of the Service Center in your area, contact your selling dealer, inquire via the web at www.perlick.com,
(800)
LIGHT BULB REPLACEMENT
To replace a defective or burnt out bulb, remove the glass light cover by pulling out on the cover, unscrew the bulb and replace it with an identical or smaller bulb. The Perlick replacement part number is 67026.
perlick.com 7