General Information

Refrigeration and Temperature Control

The cabinet is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of 36-41 degrees F. The control is factory set at 38 degrees F.

 

 

4

 

3

5

 

 

2

 

6

 

1

COLD

 

 

 

 

OFF

The condenser fan motor turns off and on with the compressor. The evaporator fan motor is on all the time.

NOTE:

Cabinet Temperatures lower than 34° will not allow for proper defrosting of the evaporator coil. If defrosting is necessary, turn the control knob to the OFF position until coil is defrosted.

Cleaning the Cabinet

Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser.

Note: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.

Adjusting the temperature

The temperature control is inside the cabinet on the left-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved.

Colder Temperatures:

Turn the adjusting screw clockwise (to the right).

Warmer Temperatures:

Turn the adjusting screw counterclockwise (to the left).

Temperature Control “OFF”:

Turn the adjusting screw completely counter- clockwise to the “O” position until a click is noted.

Cleaning the Condenser

Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure efficient operation.

Caution: Do not bend the fins while brushing the front of the condenser.

Condenser

The condenser (located behind the front grille cover) should be inspected every 30 days and cleaned, if necessary.

Failure to keep the condenser clean will cause a loss in condensing unit efficiency.

Recommended Cleaning Agents

Job

Cleaning Agent*

Comments

 

 

 

Routine Cleaning

Soap, ammonia, detergent

apply with sponge or cloth.

 

 

Can be used on all finishes.

 

 

 

Fingerprints and smears

areal 20, Lac-O-Nu, Lumin Wash,

Provides barrier film to minimize

 

O’Cedar Cream Polish

fingerprints. Can be used on all finishes.

 

 

 

Stubborn stains and

allchem Concentrated Cleaner,

rub lightly, using dry or damp

Discolorations

Samae, Twinkle, Zud Restoro,

cloth in the direction of polish

 

grade F or FFF Italian Pumice,

lines on the stainless steel.

 

Whiting or Talc, Liquid Nu Steel,

 

 

Copper’s or Revere Stainless Steel

 

 

Cleaner, Lumin Cleaner, Sta-Clean,

 

 

Cameo Copper Cleaner, Allen Polish

 

 

highlite, Penny-Brite, Copper Brite

 

 

 

 

*Use of propriety names is intended only to indicate a type of cleaner and does not constitute an endorsement.Omission of any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on

the package. Note: Do Not Use Steel Wool or Scouring Pads to clean stainless steel.