Perlick Z2151 manual Retrofitting Single Valve Couplers, 27500F, Troubleshooting

Models: Z2151

1 2
Download 2 pages 7.78 Kb
Page 1
Image 1
Troubleshooting

 

Troubleshooting

Problem:

Beer flow is slower with Smart Coupler

 

than with standard Perlick coupler.

OPERATING INSTRUCTIONS SMART COUPLER with Empty Keg Sensor

Probable Cause: Beer Flow Control Handle is in CLEAN position.

Solution:

Slowly turn Beer Flow Control Handle to ON position.

 

 

Problem:

Beer does not flow after keg is tapped.

Probable Cause: Smart Coupler has locked up.

Solution:

First, turn Beer Flow Control Handle to OFF position then

 

turn Beer Flow Control Handle to CLEAN position. Wait

 

five seconds then turn Beer Flow Control Handle to

 

ON position.

Probable Cause: Beer Flow Control Handle is OFF.

Solution:

Turn Beer Flow Control Handle to CLEAN position.

 

Wait five seconds then turn Beer Flow Control Handle to

 

ON position.

Probable Cause:

Probe or Smart Coupler is dirty.

No. 27500F

Smart Coupler with Empty Keg Sensor

Part No.

27500F

The Smart Coupler* combines a standard Perlick single-valve keg coupler with a specially-designed keg sensor that eliminates the line loss that normally follows every empty keg. Fresh kegs can be drawn off immediately. The beer lines are always full of beer.

Saves time

Reduces beer waste

Increases beer profits

Reduces aggravation

Solution:

Clean Smart Coupler.

Probable Cause: Out of gas.

Solution:

Reestablish gas flow.

 

 

Problem:

Excessive foam.

Probable Cause: Beer temperature too high. Excessive beer flow rate. Beer is over-carbonated

Solution:These problems are not caused by the Smart Coupler. Follow established procedures to correct the problem.

8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060

Fax 414-353-7069Toll Free 800-558-5592E-Mail: Perlick@Perlick.com • www.Perlick.com

IMPORTANT!

To ensure your complete satisfaction,

please read these instructions before using Perlick’s Smart Coupler.

Retrofitting Single Valve Couplers

Perlick single valve keg couplers can be retrofitted to function as Smart Couplers. Simply replace the probe with Perlick’s No. 40119 empty keg sensor.

1. Remove probe washer from bottom of probe.

2.Remove retaining screw and yoke assembly.

3.Lift probe out of body.

4.Install Perlick’s empty keg sensor.

When replacing probe washer make sure the “V”-groove surface

faces “down”.

Perlick’s Empty Keg Sensor

No. 40119

(Probe Washer Not Included)

Form Z2151

* U.S. Patent #5,630,411

04.06.04

 

 

Page 1