to the normal use of your Compact Disc player, Tuner, Cassette Deck, etc.

Always ensure that there is adequate ventilation around the 200P and sufficient space to circulate air both below and above the unit. Do not place unit directly onto carpeted surfaces.

PRODUCT SUPPLIED WITHOUT

MAINS PLUG

If your unit comes with a 3-core cable but without a plug, make certain LIVE and NEUTRAL leads are connected correctly to your plug terminals. Check that the terminals are screwed down firmly and no loose strands of wire are present.

IMPORTANT : The wires of the mains/line lead in this unit are coloured in accordance with the following code :

BROWN

LIVE

BLUE

NEUTRAL

GREEN/YELLOW

EARTH/GROUND

As the wire colours in the mains lead of this unit may not correspond exactly with those coloured markings on the terminals of your plug proceed as follows:

-The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N, or colour coded BLUE or BLACK.

-The wire which is coloured BROWN must be connected to the terminal which is marked with the letter P or L, or colour coded BROWN or RED.

- The wire which is coloured GREEN/YELLOW must be connected to the terminal which is marked with the

letter E, or colour coded GREEN/YELLOW or GREEN.

-

Note : Any modifications to the mains/line voltage setting within your 200P may only be carried out by a qualified Perreaux service agent. Failure to recognise this warning will void any warranty.

FRONT PANEL

1.POWER ON INDICATOR

The red LED indicator behind the smoked panel on the front panel will illuminate when the power is turned on.

REAR PANEL

2.UNBALANCED INPUT SOCKETS These are high quality gold plated sockets which are highly conductive, corrosion resistant, and provide less potential for corrosion induced distortion. Inputs are clearly marked Left and Right. Care should be taken to maintain channel integrity. Refer to section SPECIFICATIONS for detail on input sensitivity and impedance's.

3.BALANCED INPUT SOCKETS

The 200P feature directly driven balanced inputs. The use of good quality balanced line cable into the balanced input cause the input signal to be relatively immune to noise and external effects caused by the use of long interconnect cables, helps reduce hum

loop noise and aids in the cancellation of distortion products.

Balanced Line input pin configuration

Pin 1

EARTH / Ground

Pin 2

HOT / Phase

Pin 3

COLD / Anti-phase

4.INPUT CONFIGURATION SWITCH This toggle switch allows selection of either the balanced or unbalanced inputs. Input leads should be connected to one type of input only i.e. do not connect to both the unbalanced and balanced inputs at one time.

5.MAINS ON/OFF ROCKER SWITCH

Depress this switch to the right turn power ON. As mute relay circuitry is employed in the 200P, full output is muted for 1 to 2 second after the power switch is actuated.. Depress this switch to the left

(0)to turn the 200P off at which time the power amplifier outputs will be disconnected.

I

=

ON

0

=

OFF

6.MAINS/LINE INPUT RECEPTACLE & FUSE HOLDER

This receptacle accepts the female end of the mains power cord. For more information regarding MAINS/LINE VOLTAGE and connection see the relevant sections.

4