If you require the voltage setting to be altered, e.g. relocation to another area, city or country, or extraordinarily high or low voltages, contact your Perreaux dealer. This modification must only be performed by qualified service personnel.

Note: Always ensure the unit is disconnected from the Mains/Line supply before any covers are removed.

MAINS/LINE FUSE

The Perreaux 200P is equipped with a user serviceable mains/line fuse. Above the mains/line cord is the mains/line fuse holder. In the unlikely event of fuse failure always replace with the same type and value fuse. Remember, fuses do not usually blow without a reason. Any doubts about fuse failure should be conveyed directly to your Perreaux dealer.

The fuse ratings are:

100-125V 2SB SLOW BLOW 8A Continuous

200-250V 2SB SLOW BLOW 6A Continuous

Note: Always ensure your 200P is disconnected from the Mains/Line supply before attempting to change the Mains/Line fuse.

RAIL FUSES

The Perreaux 200P has 4 internal fuses for amplifier protection. In the unlikely event of internal fuse failure consult your Perreaux dealer. The internal fuses are not user serviceable and only authorised personnel may replace the internal fuses.

Fuse Rating -3AG Normal Acting 6 Amp

SERIAL NUMBER

All Perreaux units are allocated a unique serial number which are recorded at the factory against build details. If you should require information about your unit, providing the serial number will help achieve a prompt reply.Keep a copy of all your serial numbers in a safe place. The ability to identify and prove ownership can be very useful.

SPECIFICATIONS

Tested at 120 / 220 / 230 / 240V ac mains voltage after initial 10 minute warm up period

POWER OUTPUT

200 watts RMS per channel continuous both channels driven into 8from 20Hz to 20kHz at no more than 0.02% THD

300 watts RMS into 4FREQUENCY RESPONSE

±0.25dB from 20Hz to 20kHz

TOTAL HARMONIC DISTORTION 0.02% THD worst case prior to clipping 0.004% THD @ 1KHz

HUM, NOISE

-95dB unweighted referenced to rated output

INPUT SENSITIVITY

Balanced 0.6V RMS

Unbalanced 1.2V RMS

INPUT IMPEDANCE

Balanced 3.3k

Unbalanced 22k

DYNAMIC HEADROOM 1.9dB

CURRENT OUTPUT

24 Amperes peak per channel

DRIVER STAGE

Class A

OUTPUT STAGE

Class A / AB

DIMENSIONS (not including handles and terminals)

HEIGHT x WIDTH x DEPTH

88mm x 482mm x 460mm 3.5" x 19.0" x 18.1"

NETT WEIGHT 17.0kg (37.5lb)

7