Preliminary adjustment of needle height

1

Preliminary adjustment of needle height

Requirement

With the needle bar at b.d.c. there must be a clearance of 16.5 mm between needle holder and needle plate.

2

1

16,5 mm

Move needle bar 1 (screw 2) according to the requirement. Make sure that, when looking in the feed direction, the needle retaining screw points to the right.