Pfaff 483, 481 service manual

Models: 481 483

1 32
Download 32 pages 30.27 Kb
Page 16
Image 16
Manual background

10Needle rise, final adjustment of needle bar height and bobbin case positioning finger

Requirement

With the stitch length set at “0” and the needle bar at a position 1.8 mm past b.d.c. (cylindrical pin in hole “4”)

1.the hook point must be opposite the center line of the needle and the top edge of the needle eye must be 0.8 mm below the bottom edge of the sewing hook.

2.there must be a clearance of 0.5 mm between the lug of positioning finger 3 and the inside edge of the positioning slot.

4

0,8 mm

2

3

0,5 mm

1

Adjust the hook (screws 1) without shifting it and the needle bar (screws 2) without turning it according to requirement 1.

Set lug of positioning finger 3 into the slot in the bobbin case base; adjust and fix it according to requirement 2.

PFAFF 15

Page 16
Image 16
Pfaff 483, 481 service manual