Philips Semiconductors Product specification
TOPFET high side switch BUK205-50Y SMD version of BUK201-50Y

DYNAMIC CHARACTERISTICS

Tmb = 25 ˚C; VBG = 13 V
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Inductive load turn-off
-VLG Negative load voltage1VIG = 0 V; IL = 7.5 A; tp = 300 µs152025V
Short circuit load protection2VIG = 5 V; RL 10 m
td sc Response time - 90 - µs
ILLoad current prior to turn-off t < td sc -42- A
Overload protection3
IL(lim) Load current limiting VBL = 9 V; tp = 300 µs284052A

SWITCHING CHARACTERISTICS

Tmb = 25 ˚C, VBG = 13 V, for resistive load RL = 13 .
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
During turn-on to VIG = 5 V
td on Delay time to 10% VL-16-µs
dV/dton Rate of rise of load voltage - 1 2.5 V/µs
t on Total switching time to 90% VL-40-µs
During turn-off to VIG = 0 V
td off Delay time to 90% VL-30-µs
dV/dtoff Rate of fall of load voltage - 1.2 2.5 V/µs
t off Total switching time to 10% VL-50-µs

CAPACITANCES

Tmb = 25 ˚C; f = 1 MHz; VIG = 0 V
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Cig Input capacitance VBG = 13 V - 15 20 pF
Cbl Output capacitance VBL = VBG = 13 V - 415 580 pF
Csg Status capacitance VSG = 5 V - 11 15 pF
1 For a high side switch, the load pin voltage goes negative with respect to ground during the turn-off of an inductive load. This negative voltage
is clamped by the device.
2 The load current is self-limited during the response time for short circuit load protection. Response time is measured from when input goes
high.
3 If the load resistance is low, but not a complete short circuit, such that the on-state voltage remains less than VBL(TO), the device remains in
current limiting until the overtemperature protection operates.
July 1996 5 Rev 1.000