1. Relationship between the condition of the air conditioner and pressure and electric current
Cooling Mode Heating Mode
Condition of the air
conditoner Low Pressure High Pressure Electric current
during operation Low Pressure High Pressure Electric current
during operation
Insufficient refrigerant
(gas leakage)
Clogged capillary tube
or Strainer
Short circuit in the
indoor unit
Heat radiation
deficiency of the
outdoor unit
Inefficient compression
Carry on the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.

12.2. Breakdown Self Diagnosis Function

Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of
three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below
breakdown diagnosis method:
Press CHECKbutton at remote control continuously for more than five seconds to turn on the diagnosis mode, H11will be
displayed at remote control.
By pressing the TMER button once, next error code will be displayed; press Vbutton once, previous error code will be
displayed.
If error code displayed matches the error code saved in unit memory (abnormality detected), beep, beep, beep....sounds will
be heard for 4 seconds and Power LED will light on. Otherwise, one beepsound is heard.
If CHECKbutton is press again or without any operation for 30 seconds, the diagnosis mode will turn off.
68
CS-E15DB4EW CU-E15DBE / CS-E18DB4EW CU-E18DBE / CS-E21DB4ES CU-E21DBE