12ENGLISH

6Clean the protective screen and the UV light bulb with a damp cloth.

7Reinsert the UV light bulb.

To reinsert the light bulb, align the bottom of the light bulb with the metal clasp and push the bulb into the clasp.

8Reinsert the protective screen.

To reinsert the screen, align the pegs on the screen with the slots on the reflective surface near the UV light bulb. Push the screen straight into the slots on the sanitizer.

Storage

-If you are not going to use the product for an extended period of time, unplug it from the electrical outlet, clean it and store it in a cool and dry place away from direct sunlight.You can use the cord wrap to store the power cord in an organized manner.

Replacement

Brush head

-Replace Sonicare brush heads every 3 months to achieve optimal results.

-Use only compatible Sonicare replacement brush heads.

UV light bulb

-Replacement UV bulbs are available through your Sonicare Consumer Care Center in North America by calling 1-800-682-7664. Outside North America, contact your local Philips Consumer Care Center.

Disposal

-The rechargeable battery inside your Sonicare cannot be replaced, but

is easy to remove for recycling. At the end of product life and prior to disposal, please remove the rechargeable battery from the handle by following the instructions below.

- Do not throw away the appliance or the UV light bulb (bulb contains mercury) with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment.

- If you have any recycling questions, contact your local waste management office.