Kvaser LAPcan / LAPcan II Hardware Guide

7(19)

 

 

5 Technical data, Kvaser LAPcan and Kvaser LAPcan II

CAN channels

2 (CAN 2.0A and 2.0B active)

 

 

CAN Transceivers

The transceivers are integrated into the DRVcans.

 

 

CAN Controllers

Philips SJA 1000

 

 

Microcontroller

Siemens SAB-C161O (16 MHz)

 

 

Baudrate

5 kbit/s ... 1 Mbit/s

 

 

Timestamp resolution

8 s

 

 

Error Frame Detection

Yes, both channels

 

 

Error Frame Generation

Yes, both channels

 

 

Hardware requirements

IBM PC AT or 100% compatible; PC-Card slot type II

 

or III

PC interface

PC-Card Version 2.0 (PCMCIA) or compatible

 

 

Current consumption

110 mA for the Kvaser LAPcan plus the current of the

 

DRVcans

Software requirements

Windows 95 / Windows NT 4.0 or later

 

 

Configuration

Done by software (Plug & Play if OS supports it.)

 

 

Dimensions

PC-Card type II (ca. 85 mm x 64 mm x 5 mm)

 

 

Operating temperature

0 ºC ... +55 ºC

 

 

Non-operating

-25 ºC ... +70 ºC

temperature

 

Relative Humidity

0% ... 85% (non condensing.)

 

 

Kvaser AB, Mölndal, Sweden — www.kvaser.com