SETUP (Continued)

SETTING THE TIMER

To set the 24 Hour On/Off Timer function.

PROGRAM NUMBER

TIMER RECORDING TIME START/STOP

TIMER RECORDING TAPE SPEED

1

12 : 00A a 12 : 00A

08

2

12 : 00A a 12 : 00A

08

3

12 : 00A a 12 : 00A

08

4

12 : 00A

a 12 : 00A

08

5

12 : 00A

a 12 : 00A

08

6

12 : 00A

a 12 : 00A

08

7

12 : 00A

a 12 : 00A

08

MON:,TUE :,WED :,

THU :,FR I :,SAT :,

SUN:,

DAY OF WEEK AND PROGRAM NUMBER

1:TIMER will record for the time set for PROGRAM NUMBER 1

2:TIMER will record for the time set for PROGRAM NUMBER 2

3:TIMER will record for the time set for PROGRAM NUMBER 3

4:TIMER will record for the time set for PROGRAM NUMBER 4

5:TIMER will record for the time set for PROGRAM NUMBER 5

6:TIMER will record for the time set for PROGRAM NUMBER 6

7:TIMER will record for the time set for PROGRAM NUMBER 7

:No recording

TIMER Display Format Description

1.Press the START/STOP button.

The program number (1) flashes on/off.

2.Press the SET button. The start hours flash on/off.

3.Press the UP or DOWN button until the desired number appears on the monitor.

Remember to watch the AM/PM indicator when setting the hours.

4.Press the SET button. The start minutes flash on/off.

5.Press the UP or DOWN button until the desired number appears on the monitor.

6.Press the SET button. The stop hours flash on/off.

7.Repeat steps 3 through 5 to set the stop hours and minutes. Remember to watch the AM/PM indicator when setting the hours.

8.Press the SET button. The timer recording speed flashes on/off.

9.Press the UP or DOWN button until the desired number appears on the monitor.

10.Press the SET button after setting the timer recording speed. The program number of the next lower line flashes on/off.

11.Repeat steps 2 through 9 to set the program to the other program numbers.

12.Press the SET button after setting the program numbers (1) through (7).

The two program event locations of MON flash on/off.

13.Press the SET button. The first program event location of MON flashes.

14.Press the UP or DOWN button until the desired program number appears on the monitor.

15.Press the SET button. The other program event location of MON flashes on/off.

16.Press the UP or DOWN button until the desired program number appears on the monitor.

Notes:

If you do not need to timer record two events a day, mark either event with an asterisk ().

If two asterisks are displayed, no timer record- ing is made on that day.

17.After setting two program event locations of MON, press the SET button. The two program event locations of the next day of the week flashes on/off.

18.Press the SET button. The first program event location of the next day flashes.

19.Repeat steps 12 through 16 to set the program event locations up to SUN.

20.Press the START/STOP button when the TIMER has been set.

15

PHILIPS LTC3924/62 (E) QR34071

Page 16
Image 16
Philips LTC 3924, LTC 3962 manual To set the 24 Hour On/Off Timer function

LTC 3924, LTC 3962 specifications

Philips LTC 3962 and LTC 3924 are two prominent LED drivers designed to enhance lighting efficiency and performance in various applications. These devices stand out for their innovative technology and key features, making them ideal choices for both residential and commercial lighting solutions.

The Philips LTC 3962 is a high-performance LED driver that offers a wide input voltage range, catering to various lighting designs. It supports constant current output, ensuring stable lighting performance over time and aiding in superior color consistency across LED arrays. With its compact design, the LTC 3962 is well-suited for applications requiring space-efficient solutions. Notably, it features built-in thermal protection and supports dimming options, allowing users to adjust brightness levels according to their preferences and energy-saving needs.

On the other hand, the Philips LTC 3924 is designed for higher power applications, enabling it to drive larger LED arrays effectively. It boasts advanced power management technologies, which enhance energy efficiency by minimizing losses during operation. The LTC 3924 supports dimmable LED drivers, while its robust architecture accommodates a wide variety of LED types, ensuring flexibility for design engineers. One of the standout characteristics of the LTC 3924 is its ability to interface seamlessly with smart lighting systems, paving the way for enhanced connectivity and control.

Both the LTC 3962 and LTC 3924 integrate advanced features such as over-voltage, under-voltage, and over-current protection, ensuring reliable performance in varying conditions. They also come with built-in diagnostic features, which allow for easy troubleshooting and maintenance, thus extending the lifespan of the LED lighting systems they power.

In summary, Philips LTC 3962 and LTC 3924 are exceptional LED drivers, engineered with innovative technologies and features that cater to the evolving needs of modern lighting. Their emphasis on efficiency, flexibility, and reliability makes them ideal candidates for a wide range of applications, ensuring optimal performance in any setting. Whether for smart homes, commercial spaces, or industrial environments, these LED drivers represent a significant advancement in lighting technology, driving the future of energy-efficient illumination.