DESIGNED BY PHILIPS DESIGN HONG KONG 2003

product details

Technical descriptions

Mechanical

Yellow powder painted high pressure die-cast aluminium housing

UV-protected clear glass cover – 5mm thick

Stainless steel plate to support L E D unit

Operating temperature = - 40° C to +70° C

I P 6 5

Wind load at 200 km/hr of less than 40 Newton force

Threaded base for 1 inch in diameter size of pipe (other size can be applied with the reducer or enlarger)

Electrical

Standard type using nominal operating voltage of 48Vdc or 220-240Vac; 24 Vdc systems are available upon request

Terminal block for 2 x 1.5mm2 cables

Power consumption: 5W for 48Vdc Type A version, 7W for 220-240Vac Type A version and 12W for 48Vdc Type B version

Constant current 100mA for Type A, 250mA for Type B

Surge protection device integrated: according to Institute of Electrical and Electronics Engineers ( I E E E ) requirement

Optical

Luminous intensity of greater than 10 cd for low intensity type A obstacle light and greater than 32 cd for low intensity type B obstacle light

Horizontal radiation coverage 360°

Vertical radiation coverage 50°

Color: aviation red, choice of fixed or flashed light

Installation

Pipe installation: the standard luminaire comes with threaded base – ready to be installed with threaded pipe of 1 inch in diameter (other size of pipe – use standard reducer or enlarger)

To attach ObstiVision with existing antenna / pipe or wall-mounted installation, the mounting kit is required.

Accessories

Control box *

Photo switch and sensor

Mounting accessories *

3-way and 4-way junction box for through-wiring

Solar cell

Product compliances

Product compliance with International Civil Aviation Organization ( I C AO ) standards and recommended practices – Aerodromes Annex 14 Volume 1, 3rd edition – July 1999, Chapter 6.

Federal Aviation Administration ( FA A ) standard

*please check with your local Philips agent for details

Specifications subject to modification

All intellectual property rights reserved, Koninklijke Philips Electronics N.V.

Dimensional Sketches

Ø113

240

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96

 

 

66

 

 

G1”

dimensions in mm

 

 

 

 

 

 

 

 

Ordering Data

Product Code

Description

Ordering Number

XGP388 48Vdc A

ObstiVision 48Vdc Type A

9199 186 76132

XGP388 220-240Vac

ObstiVision 220-240Vac 50-60Hz Type A

9199 186 77132

50-60Hz A/AF

(flasher selector is integrated)

 

XGP388 48Vdc B

ObstiVision 48Vdc Type B

9199 186 76532

ZGB388 220-240Vac

Control Box 220-240Vac 50-60Hz input

9199 186 72732

50-60Hz / 48Vdc L P

48Vdc output with photo switch

 

ZBG388 220-240Vac

ontrol Box 220-240Vac 50-60Hz input

9199 186 72232

50-60Hz / 48Vdc L T

48Vdc output with timer

 

ZGP388 TW3

3-way throughwiring junction box

9199 186 71032

ZGP388 TW4

4-way throughwiring junction box

9199 186 71132

ZPP388

Mounting Kit - pipe installation

9199 186 70032

ZVB388

Mounting Kit - building top installation

9199 186 70132

ZWB388

Mounting Kit - wall mounted installation

9199 186 70232

ZGL388 P

Photo sensor

9199 186 70332

Page 5
Image 5
Philips ObstiVision manual Technical descriptions, Dimensional Sketches, Ordering Data