4.Ballast specification for T5 VHO
and HO Extreme Temperature lamps
4.1.First start-up
During the first
4.2. Ballast ordering, electrical and technical data
|
| Lamp |
| Maximum |
| Min. | |
No. of | Input | Starting | Catalog | Input Power | Ballast | Line Current | Starting |
Lamps | Volts | Method | Number | ANSI (Watts) | Factor | (Amps) | Temp (˚F/˚C) |
T5 VHO |
|
|
|
|
|
|
|
1 | 277 | PS | 116W | 1.1 | 0.42 | ||
1 | 347 | PS | 116W | 1.1 | 0.35 | ||
1 | 480 | PS | 116W | 1.1 | 0.24 | ||
2 | 277 | PS | 206W | 1.0 | 0.74 | ||
2 | 347 | PS | 206W | 1.0 | 0.59 | ||
2 | 480 | PS | 206W | 1.0 | 0.43 | ||
T5 HO |
|
|
|
|
|
|
|
1 | 120 | PS | ICN2S5490CWL | 62W | 1.0 | 0.52 | |
1 | 277 | PS | ICN2S5490CWL | 62W | 1.0 | 0.23 | |
2 | 120 | PS | ICN2S5490CWL | 120W | 1.0 | 1.00 | |
2 | 277 | PS | ICN2S5490CWL | 117W | 1.0 | 0.43 | |
1 | 347 | PS | HCN2S5490CWL | 62W | 1.0 | 0.18 | |
1 | 480 | PS | HCN2S5490CWL | 62W | 1.0 | 0.13 | |
2 | 347 | PS | HCN2S5490CWL | 120W | 1.0 | 0.35 | |
2 | 480 | PS | HCN2S5490CWL | 119W | 1.0 | 0.25 | |
3 | 120 | PS | ICN4S5490C2LSG | 182W | 1.0 | 1.52 | |
3 | 277 | PS | ICN4S5490C2LSG | 179W | 1.0 | 0.66 | |
4 | 120 | PS | ICN4S5490C2LSG | 240W | 1.0 | 2.00 | |
4 | 277 | PS | ICN4S5490C2LSG | 234W | 1.0 | 0.86 | |
3 | 347 | PS | HCN4S5490C2LSG | 188W | 1.0 | 0.54 | |
3 | 480 | PS | HCN4S5490C2LSG | 186W | 1.0 | 0.39 | |
4 | 347 | PS | HCN4S5490C2LSG | 239W | 1.0 | 0.69 | |
4 | 480 | PS | HCN4S5490C2LSG | 237W | 1.0 | 0.50 |
Above specifications subject to change without notice.
4.3. Description of the ballast
•Quick programmed start: 1.2 second warm start, preheating the lamp electrodes; this enables the lamps to be switched on and off without reducing life.
•Intellivolt®
•End of Life Lamp (EOLL) protection: removes power to lamps upon lamp failure.
•
•Low minimum starting temperature for cold applications.
10 OEM Design Guide Philips T5 VHO and HO Extreme Temperature Lamps and Ballasts