Philips T5VHO Technical data for installation, Mains operation, Switching cycle effects, 120-277V

Models: T5VHO

1 14
Download 14 pages 40.59 Kb
Page 11
Image 11
A = 1.18" (30mm)

A = 1.18" (30mm)

B = 1.70" (43.2mm)

C = 16.34" (415mm)

D = 16.70" (424.4mm)

Figure 4.1. T5 VHO and T5 HO 4 lamp case dimensions

A = 1.02" (26mm)
B = 1.18" (30mm)

C = 15.65" (397.5mm)

D = 16.34" (415mm)

E = 16.70" (424.2mm)

Figure 4.2. T5 HO 2 lamp case dimensions

4.4.Technical data for installation

 

Mains operation

 

Rated mains voltage

120–277V, 347–480V,

 

and 277–480V

Tolerances for safety:

+/– 10%

Mains frequency

50/60 Hz

Power factor

>= 0.99

DC voltage operation (during emergency back-up)

Because of the run up, T5 VHO and HO Extreme Temperature lamps (and therefore ballast) are not suitable in combination with emergency situations.

4.5. Switching cycle effects

The rated average lamp life of T5 lamps is negatively affected when the switching frequency is higher than the IEC cycle (3 hrs cycle: 2 hours and 45 minutes on, 15 minutes off).

OEM Design Guide Philips T5 VHO and HO Extreme Temperature Lamps and Ballasts 11

Page 11
Image 11
Philips T5VHO Technical data for installation, Mains operation, DC voltage operation during emergency back-up, 120-277V