© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
User manual Rev. 02 — 23 May 2005 123 of 133
Philips Semiconductors UM10109
P89LPC932A1 User manual
18.17 User configuration bytes

A number of user-configurable features of the P89LPC932A1 must be defined at

power-up and therefore cannot be set by the program after start of execution. These

features are configured through the use of an Flash byte UCFG1 shown in Table 101

Read Sector CRC Input parameters:
ACC = 05h
R7= sector address
Return parameter(s):
R4= CRC bits 31:24
R5= CRC bits 23:16
R6= CRC bits 15:8
R7= CRC bits 7:0 (if no error)
R7= error status (if error)
Carry= set on error, clear on no error
Read Global CRC Input parameters:
ACC = 06h
Return parameter(s):
R4= CRC bits 31:24
R5= CRC bits 23:16
R6= CRC bits 15:8
R7= CRC bits 7:0 (if no error)
R7= error status (if error)
Carry= set on error, clear on no error
Read User Code Input parameters:
ACC = 07h
R4= address (MSB)
R5= address (LSB)
Return parameter(s):
R7= data
Table 99: IAP function calls …continued
IAP function IAP call parameters
Table 100: Flash User Configuration Byte (UCFG1) bit allocation
Bit 76543210
Symbol WDTE RPE BOE WDSE - FOSC2 FOSC1 FOSC0
Unprogrammed
value
01100011
Table 101: Flash User Configuration Byte (UCFG1) bit description
Bit Symbol Description
0 FOSC0 CPU oscillator type select. See Section 2 “Clocks for additional information. Combinations other than those
shown in Tabl e 102 are reserved for future use should not be used.
1FOSC1
2FOSC2
3- reserved