35
Appendix B - Connector and CablePin Outs

Pin Outs for V.35 Female Connector (DTE)

V.35 (DTE) Signal
AChassis Ground <->
BSignal Ground <->
CRequest to Send ->
DClear to Send <-
EData Set Ready <-
FReceive Line Signal Detect <-
HData Terminal Ready ->
JLocal Loopback ->
PTx Data ->
RRx Data <-
STx Data ->
TRx Data <-
UTx Clock Out ->
VRx Clock In <-
WTx Clock Out ->
XRx Clock In <-
YTx Clock In <-
AA Tx Clock In <-

Pin Outs for DB-25 Male to DB-25 Female RS-232 Data &

AUX/Console Cable

The cable supplied with the BR Router is twenty-five conductors, straight through.
Connections on both the auxiliary interface and the data interface follow the
standard RS-232 pin outs. Note that the data interface may be set for synchronous
operation and in this mode the data interface will use the clock lines provided by
RS-232.