53.COLOR TUNE
Function
External control equipment can adjust RGB each color that a plasma monitor
wants to emphasize. |
|
|
| |
Transmission Data |
|
|
| |
|
|
|
|
|
| DFH 80H 60H | 0DH | 07H DATA00 to DATA06 CKS | |
DATA00:RED | 00H : | |||
|
| : |
|
|
|
| 20H | : 0 |
|
|
| : |
|
|
|
| 40H | : +32 |
|
DATA01:GREEN | 00H : | |||
|
| : |
|
|
|
| 20H | : 0 |
|
|
| : |
|
|
|
| 40H | : +32 |
|
DATA02:BLUE | 00H : | |||
|
| : |
|
|
|
| 20H | : 0 |
|
|
| : |
|
|
|
| 40H | : +32 |
|
DATA03:YELLOW | 00H : | |||
|
| : |
|
|
|
| 20H | : 0 |
|
|
| : |
|
|
|
| 40H | : +32 |
|
DATA04:MAZENTA | 00H : | |||
|
| : |
|
|
|
| 20H : 0 | ||
|
| : |
|
|
|
| 40H : +32 | ||
DATA05:CYAN | 00H : | |||
|
| : |
|
|
|
| 20H : 0 | ||
|
| : |
|
|
|
| 40H : +32 | ||
DATA06:RESET | 00H : OFF | |||
|
|
| 51 |
|