55.PRESENT TIME SETTING
Function
External control apparatus sets up the present time of a plasma monitor. Transmission Data
DFH 80H 60H 31H 03H DATA00 to DATA02 CKS
DATA00 Day of the week
DATA01 HOUR | |
| 10H~19H:10~19 |
| 20H~23H:20~23 |
DATA02 minute | |
| 10H~19H:10~19 |
| 20H~29H:20~29 |
| 30H~39H:30~39 |
| 40H~49H:40~49 |
| 50H~59H:50~59 |
ACK |
|
7FH 60H 80H 31H 00H CKS
56.MULTI MODE Select
Function
External control apparatus changes MULTI MODE of a plasma monitor. Transmission Data
DFH 80H 60H 03H 03H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING) 01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
05H : Multi mode 16 screens
06H : Multi mode 25 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
54