Solid State Temperature Control (SSTC)
1 Switch and Indicator Locations and Function:
On / Off switch:
Turns the control on or off. The power indicator
will be illuminated when the switch is in the on position.
Primary / Backup select switch:
In appliances with primary AND a backup control, this switch selects the control that will manage temperature in the appliance. When the switch is in the single dot position, power is diverted to the primary control, typically an I12 cooking computer. When the switch is moved to the two dot position, power is diverted to the Backup control.
Melt / No Melt select switch:
In the melt cycle position, melt cycle will be executed when the appliance first starts up. This melt cycle will end automatically when the temperature conditions are correct to allow full heat. Operators may bypass a running melt cycle by moving the switch to the full heat position.
Temperature Set Knob:
The position of the pointer sets the cooking temperature of the control. Scales are shown in Fahrenheit and Celsius scales.
Power Indicator:
This green indicator shows the control is turned on.
Heat Demand Indicator:
This LED indicator shows when the control is demanding heat.
Heat Feed Back/Fault Indicator:
This indicator shows when the appliance is heating in response to a heat demand. Under normal conditions, this light will follow the head demand indicator. This indicator is also used to flash conditions for probe faults, drain valve open conditions, or, boil out operations.