Warning

Warning message

Comment or clarification

code

 

 

 

 

 

4012

The command is not availbale when

 

MODE=RECONFIG

 

HP SSA scripting error messages

Error codeError message

Comment or clarification

 

 

 

0

No error exists. The program completed

 

 

successfully.

2053

Too many coinciding expansion, migration,

The new configuration requires more

 

or extension operations

transformations than are possible at one time. For

 

 

example, you cannot expand a logical volume and

 

 

transform its RAID level at the same time.

 

 

 

2056

Controller does not support license keys

The controller does not support license key entry or

 

 

deletion.

2059

Invalid license key

The entered license key is not a valid license key.

2064

Controller does not support SSP

The controller does not support SSP functions.

2817

Invalid Action

The requested actions are invalid, for example,

 

 

combining -resetwith capture mode.

2818

Invalid Method

The method must be either Custom or Auto.

2819

Invalid Controller

An invalid controller value was specified.

2821

No controllers detected

No controllers were detected. This error applies to

 

 

Input mode only.

2823

Invalid Rebuild Priority

The specified rebuild priority is not supported.

2824

Invalid Expand Priority

The specified expand priority is not supported. This

 

 

error also occurs if the controller does not allow

 

 

expansion, and therefore does not support expand

 

 

priority.

 

 

 

2826

Array not specified

The Array command is missing from the script file.

 

 

Some commands were found that require an Array

 

 

to be specified.

 

 

 

2827

New Array ID does not match the next

The array ID in the script file does not match the

 

available Array ID

array ID of the next available array. For example, if

 

 

the configuration has an Array A and the input file

 

 

specifies Array C (without Array B), then the script

 

 

generates this error.

 

 

 

2828

New Array ID already exists

The array ID specified in the script file (in Configure

 

 

mode) already exists in the configuration. Configure

 

 

mode can only create new arrays.

 

 

 

2829

Cannot create Array

The controller will not allow a new array to be

 

 

created, either because the controller has no

 

 

unassigned physical drives attached or because the

 

 

maximum number of arrays or logical drives has

 

 

been reached already.

 

 

 

2830

Cannot expand Array

The Array could not be expanded, either because

 

 

the controller does not support expansion, or the

 

 

current configuration does not allow expansion to

 

 

occur on the array.

 

 

 

2831

Cannot change Array Spare

The spare state of the array could not be changed.

Operations 106