Error code

Error message

Comment or clarification

 

 

 

 

 

 

free space for the requested size

 

 

3011

Cannot extend logical drive, requested size

 

 

is too small

 

 

3012

Cannot specify both SIZE and SHRINKSIZE

The input file cannot specify both a SIZE and

 

 

 

SHRINKSIZE parameter.

 

3013

Cannot shrink Array

The array shrink operation was not successful.

 

3014

Cannot move Array

The array move operation was not successful.

 

3015

Invalid operation - Advanced Pack support

The requested operation requires a valid license key

 

 

required

to be entered.

 

 

 

 

 

3016

Spare drives cannot be specified by a count

When in Reconfigure mode, the requested spare

 

 

in Reconfigure mode

drives must be specified by their addresses. A simple

 

 

 

count cannot be used.

 

 

 

 

 

3017

Disk drives cannot be specified by a count in

When in Reconfigure mode, the requested data

 

 

Reconfigure mode

drives must be specified by their addresses. A simple

 

 

 

count cannot be used.

 

 

 

 

 

3018

Invalid number of physical disks

 

 

 

 

 

3019

Cannot create Array - no physical disks

HP SSA cannot create an array unless physical disks

 

 

specified

are specified in the input file DRIVE parameter.

 

 

 

 

 

3020

SSP must be enabled in order to perform this

For the specified operation, HP SSA requires SSP to

 

 

operation

be supported and enabled.

 

3021

Invalid connection name

 

3022

The connectionname cannot be removed

 

 

when the hostmode has a non-default

 

 

 

value.

 

 

3023

Invalid Host Mode

 

 

 

 

 

3024

Invalid Adapter ID

 

 

 

 

 

3025

This controller does not have host mode

 

 

modification capability

 

 

 

 

 

 

3026

You need to have administrator rights to

 

 

continue

 

 

3027

Another instance of HP SSA is already

 

 

running (possibly a service). Please

 

 

 

terminate the HP SSA application before

 

 

 

running HP SSA scripting.

 

 

3028

Invalid Drive Cache setting. Valid options

 

 

are ENABLE and DISABLE.

 

 

3029

Invalid or out of order Command

Verify the ordering of the commands in the input

 

 

 

configuration file.

 

3030

Invalid or missing Array for Reconfigure

Expecting a valid array in Reconfigure mode

 

 

 

 

 

3031

Invalid or missing Filename for Firmware

The firmware filename supplied is not a valid

 

 

Update

filename.

 

3032

Firmware Update Failed

The firmware flash operation on the controller failed.

 

3033

This controller has been configured with a

Some changes to SOULAPI are not

 

 

more recent version of software. To prevent

backward-compatible. This check prevents the use of

 

 

data loss, configuration changes to this

an older version of software on a controller

 

 

controller are not allowed. Please upgrade

configured with a newer version, possibly overriding

 

 

to the latest version to be able to continue to

changes and destroying data.

 

 

configure this controller.

 

 

 

 

Operations 109