| Error code | Error message | Comment or clarification | 
 | 
| 
 | 
 | 
 | 
 | 
| 
 | free space for the requested size | 
 | 
 | 
| 3011 | Cannot extend logical drive, requested size | — | 
 | 
| 
 | is too small | 
 | 
 | 
| 3012 | Cannot specify both SIZE and SHRINKSIZE | The input file cannot specify both a SIZE and | 
 | 
| 
 | 
 | SHRINKSIZE parameter. | 
 | 
| 3013 | Cannot shrink Array | The array shrink operation was not successful. | 
 | 
| 3014 | Cannot move Array | The array move operation was not successful. | 
 | 
| 3015 | Invalid operation - Advanced Pack support | The requested operation requires a valid license key | 
 | 
| 
 | required | to be entered. | 
 | 
| 
 | 
 | 
 | 
 | 
| 3016 | Spare drives cannot be specified by a count | When in Reconfigure mode, the requested spare | 
 | 
| 
 | in Reconfigure mode | drives must be specified by their addresses. A simple | 
 | 
| 
 | 
 | count cannot be used. | 
 | 
| 
 | 
 | 
 | 
 | 
| 3017 | Disk drives cannot be specified by a count in | When in Reconfigure mode, the requested data | 
 | 
| 
 | Reconfigure mode | drives must be specified by their addresses. A simple | 
 | 
| 
 | 
 | count cannot be used. | 
 | 
| 
 | 
 | 
 | 
 | 
| 3018 | Invalid number of physical disks | — | 
 | 
| 
 | 
 | 
 | 
 | 
| 3019 | Cannot create Array - no physical disks | HP SSA cannot create an array unless physical disks | 
 | 
| 
 | specified | are specified in the input file DRIVE parameter. | 
 | 
| 
 | 
 | 
 | 
 | 
| 3020 | SSP must be enabled in order to perform this | For the specified operation, HP SSA requires SSP to | 
 | 
| 
 | operation | be supported and enabled. | 
 | 
| 3021 | Invalid connection name | — | 
 | 
| 3022 | The connectionname cannot be removed | — | 
 | 
| 
 | when the hostmode has a  | 
 | 
 | 
| 
 | value. | 
 | 
 | 
| 3023 | Invalid Host Mode | — | 
 | 
| 
 | 
 | 
 | 
 | 
| 3024 | Invalid Adapter ID | — | 
 | 
| 
 | 
 | 
 | 
 | 
| 3025 | This controller does not have host mode | — | 
 | 
| 
 | modification capability | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
| 3026 | You need to have administrator rights to | — | 
 | 
| 
 | continue | 
 | 
 | 
| 3027 | Another instance of HP SSA is already | — | 
 | 
| 
 | running (possibly a service). Please | 
 | 
 | 
| 
 | terminate the HP SSA application before | 
 | 
 | 
| 
 | running HP SSA scripting. | 
 | 
 | 
| 3028 | Invalid Drive Cache setting. Valid options | — | 
 | 
| 
 | are ENABLE and DISABLE. | 
 | 
 | 
| 3029 | Invalid or out of order Command | Verify the ordering of the commands in the input | 
 | 
| 
 | 
 | configuration file. | 
 | 
| 3030 | Invalid or missing Array for Reconfigure | Expecting a valid array in Reconfigure mode | 
 | 
| 
 | 
 | 
 | 
 | 
| 3031 | Invalid or missing Filename for Firmware | The firmware filename supplied is not a valid | 
 | 
| 
 | Update | filename. | 
 | 
| 3032 | Firmware Update Failed | The firmware flash operation on the controller failed. | 
 | 
| 3033 | This controller has been configured with a | Some changes to SOULAPI are not | 
 | 
| 
 | more recent version of software. To prevent | 
 | |
| 
 | data loss, configuration changes to this | an older version of software on a controller | 
 | 
| 
 | controller are not allowed. Please upgrade | configured with a newer version, possibly overriding | 
 | 
| 
 | to the latest version to be able to continue to | changes and destroying data. | 
 | 
| 
 | configure this controller. | 
 | 
 | 
| 
 | 
 | Operations 109 | |