Error code

Error message

Comment or clarification

 

 

 

 

 

This error can occur when you attempt to add or

 

 

drop a spare and the current configuration does not

 

 

allow a spare state change for the array.

 

 

 

2832

Invalid physical drive. Possible reasons for

A specified physical drive is not a valid physical

 

this include: a typing error, the drive already

drive, or it cannot be placed in the array.

 

exists in an array, the drive type does not

 

 

match, or it is a failed drive.

 

2833

Invalid Spare

A specified spare is not a valid spare drive, or it

 

 

cannot be placed in the array as a spare.

2834

Invalid logical drive

The logical drive ID is not valid.

2836

New Logical Drive ID does not match the

The script file specifies a logical drive ID that is not

 

next available logical drive ID.

the first unused ID in the sequence. For example, this

 

If you are attempting to replicate a

message appears if the controller has only Logical

 

configuration that has non-consecutive

Drive 1 and the script file specifies creation of

 

logical drive numbers, then you must

Logical Drive 3 (omitting Logical Drive 2). A common

 

change the script file so that the logical drive

cause of this error is that the input file specifies

 

numbers are consecutive.

nonsequential logical drive numbers. In this case,

 

 

change the logical drive numbers in the input file so

 

 

that they are sequential.

 

 

 

2837

New Logical Drive ID already exists

This error occurs in Configure mode when the logical

 

 

drive ID specified in the script file already exists in

 

 

the configuration. In Configure mode, you can

 

 

create new logical drives only.

 

 

 

2838

Cannot create Logical Drive

The array has no free space, or the maximum

 

 

number of logical drives has been reached already.

2839

Cannot migrate Logical Drive RAID

The controller does not support RAID migration, or

 

 

migration is not possible with the current controller

 

 

configuration.

 

 

 

2841

Cannot extend Logical Drive

The controller does not support extension, or the

 

 

current controller configuration cannot be extended.

 

 

For example, extension is not possible if the array

 

 

has no free space.

 

 

 

2842

Invalid RAID

The specified RAID level is invalid or is not possible

 

 

with the current physical disk and array

 

 

configuration.

 

 

 

2843

Invalid Size

The specified size is invalid or is not possible with the

 

 

current configuration.

2844

Invalid Stripe Size

The specified stripe size is invalid, not supported by

 

 

the current RAID level, or not possible with the

 

 

current configuration.

 

 

 

2849

Invalid ClearConfigurationWithDataLoss

The valid parameters are Yes and No (default).

 

parameter

 

2850

Controller does not support Chassis Name

The controller does not support setting a chassis

 

 

name.

2851

Invalid Chassis Name

The entered chassis name is invalid. Use characters

 

 

from the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +,

 

 

:, ., /, and [space]. The name cannot end with a

 

 

space character or exceed the maximum number of

 

 

characters allowed by the controller.

 

 

 

2852

Invalid SSP State

The requested SSP state is not a valid SSP state.

2853

Cannot change SSP settings

The SSP settings cannot be changed for the controller

Operations 107