Error code | Error message | Comment or clarification |
|
|
|
|
| This error can occur when you attempt to add or |
|
| drop a spare and the current configuration does not |
|
| allow a spare state change for the array. |
|
|
|
2832 | Invalid physical drive. Possible reasons for | A specified physical drive is not a valid physical |
| this include: a typing error, the drive already | drive, or it cannot be placed in the array. |
| exists in an array, the drive type does not |
|
| match, or it is a failed drive. |
|
2833 | Invalid Spare | A specified spare is not a valid spare drive, or it |
|
| cannot be placed in the array as a spare. |
2834 | Invalid logical drive | The logical drive ID is not valid. |
2836 | New Logical Drive ID does not match the | The script file specifies a logical drive ID that is not |
| next available logical drive ID. | the first unused ID in the sequence. For example, this |
| If you are attempting to replicate a | message appears if the controller has only Logical |
| configuration that has | Drive 1 and the script file specifies creation of |
| logical drive numbers, then you must | Logical Drive 3 (omitting Logical Drive 2). A common |
| change the script file so that the logical drive | cause of this error is that the input file specifies |
| numbers are consecutive. | nonsequential logical drive numbers. In this case, |
|
| change the logical drive numbers in the input file so |
|
| that they are sequential. |
|
|
|
2837 | New Logical Drive ID already exists | This error occurs in Configure mode when the logical |
|
| drive ID specified in the script file already exists in |
|
| the configuration. In Configure mode, you can |
|
| create new logical drives only. |
|
|
|
2838 | Cannot create Logical Drive | The array has no free space, or the maximum |
|
| number of logical drives has been reached already. |
2839 | Cannot migrate Logical Drive RAID | The controller does not support RAID migration, or |
|
| migration is not possible with the current controller |
|
| configuration. |
|
|
|
2841 | Cannot extend Logical Drive | The controller does not support extension, or the |
|
| current controller configuration cannot be extended. |
|
| For example, extension is not possible if the array |
|
| has no free space. |
|
|
|
2842 | Invalid RAID | The specified RAID level is invalid or is not possible |
|
| with the current physical disk and array |
|
| configuration. |
|
|
|
2843 | Invalid Size | The specified size is invalid or is not possible with the |
|
| current configuration. |
2844 | Invalid Stripe Size | The specified stripe size is invalid, not supported by |
|
| the current RAID level, or not possible with the |
|
| current configuration. |
|
|
|
2849 | Invalid ClearConfigurationWithDataLoss | The valid parameters are Yes and No (default). |
| parameter |
|
2850 | Controller does not support Chassis Name | The controller does not support setting a chassis |
|
| name. |
2851 | Invalid Chassis Name | The entered chassis name is invalid. Use characters |
|
| from the set |
|
| :, ., /, and [space]. The name cannot end with a |
|
| space character or exceed the maximum number of |
|
| characters allowed by the controller. |
|
|
|
2852 | Invalid SSP State | The requested SSP state is not a valid SSP state. |
2853 | Cannot change SSP settings | The SSP settings cannot be changed for the controller |