; There can be multiple array specifications in the file Array = ABCDEFG...ZAAABAC... NEXT OnlineSpareMode = Dedicated AutoReplace
OnlineSpare = Port:ID,... Box:Bay,... Port:Box:Bay None N Drive = Port:ID... Box:Bay... Port:Box:Bay,... N *
;Caching Array Options
;There can be only one Caching Array specifications in the file
CachingArray = ABCDEF…ZAAABAC…
Drive = Port:ID,… Box:Bay,… Port:Box:Bay,...
;Logical Drive Options
;There can be multiple logical drive specifications in the file
;The maximum strip size depends on the number of drives in an array and the size of the controller cache
LogicalDrive = 123… max Volumes NEXT
Repeat = 0… max Volumes
RAID = 011056ADG5060
Size = NMaxMAXMBR
Sizeblocks = N
ShrinkSize = N
NumberOfParityGroups = N
NPG (same as NumberOfParityGroups)
Sectors = 3263
StripSize = 81632641282565121024
ArrayAccelerator = EnableDisable
; Caching Logical Drive Options CachingLogicalDrive = 123… max Volumes/2 RAID = 01 ;FW and Controller dependent Size = N
Sample custom capture script
Running HP SSA Scripting in capture mode captures the configuration of all array controllers on the server in a capture file. The capture file can be used in input mode with minor edits to replicate the configuration to other array controllers.
Use of the
Example: