A typical output would be:

Smart Array P421 in Slot 9

Bus Interface: PCI

Slot: 9

Serial Number: PBKTV0XTAZZ005

RAID 6 (ADG) Status: Enabled

Controller Status: OK

Hardware Revision: A

Firmware Version: 0.02-106

Rebuild Priority: Medium

Expand Priority: Medium

Surface Scan Delay: 3 secs

Surface Scan Mode: Idle

Queue Depth: Automatic

Monitor and Performance Delay: 60 min

Elevator Sort: Enabled

Degraded Performance Optimization: Disabled

Inconsistency Repair Policy: Disabled

Wait for Cache Room: Disabled

Surface Analysis Inconsistency Notification: Disabled

Post Prompt Timeout: 15 secs

Cache Board Present: True

Cache Status: OK

Accelerator Ratio: 10% Read / 90% Write

Drive Write Cache: Disabled

Total Cache Size: 1024 MB

Total Cache Memory Available: 816 MB

No-Battery Write Cache: Disabled

Cache Backup Power Source: Capacitors

Battery/Capacitor Count: 1

Battery/Capacitor Status: OK

SATA NCQ Supported: True

Spare Activation Mode: Activate on drive failure

Controller Temperature (C): 40

Cache Module Temperature (C): 0

Capacitor Temperature (C): 0

Boot Controller: True

Primary Boot Volume: logicaldrive 1

Secondary Boot Volume: logicaldrive 1

Example 2:

=> ctrl all show

Because this target consists of several devices, the output will be brief. A typical output would be:

MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn: 500805F3000BAC11)

Operations 59

Page 59
Image 59
HP Smart Storage Adstrator manual = ctrl all show