Manuals
/
HP
/
Computer Equipment
/
Software
HP
Smart Storage Adstrator
manual
Click Create Arrays with RAID
Models:
Smart Storage Adstrator
1
45
137
137
Download
137 pages
1.5 Kb
42
43
44
45
46
47
48
49
<
>
Troubleshooting
Install
Password
Fault-tolerance methods
MNPDelay
Array configuration
Diagnostics screen
Set up PXELinux
Command variable
Procedure HP Smart Array
Page 45
Image 45
3.
Click Create Arrays with RAID 0.
Operations 45
Page 44
Page 46
Page 45
Image 45
Page 44
Page 46
Contents
HP Smart Storage Administrator User Guide
Page
Contents
Optional components 130
About HP SSA
Benefits of using HP SSA
Support for configuration tasks
Procedure HP Smart Array
Array configuration guidelines
Array configuration
Minimum requirements
Native support for 64-bit and 32-bit operating systems
Launching HP SSA during Post Gen8 or later
Accessing HP SSA in the offline environment
Launching HP SSA from an ISO image all generations
Mounting the image through iLO
Burning the image to a CD or DVD
Installing the image on a PXE server
Set up PXELinux
Prerequisites
Specify the ISO image path
Configure PXELinux
Supported network file systems
Accessing HP SSA in the online environment
Launching HP SSA on a local server
Hpssa- h
Http//servername2301
Operations
Icon and key stroke legend
Using the HP SSA GUI
Navigating the GUI
Configure screen
When a controller is selected, the following elements appear
Diagnostics screen
HP SSA help
Configuration tasks
Configuring a controller
Performing a Configuration task
HP SSD Smart Path
Operations
Rapid Parity Initialization
SSD Over Provisioning Optimization
Operations
Changing the Spare Management mode
Changing the Spare Activation Mode
Operations
Cache Manager
Operations
About HP SmartCache
Enable HP SmartCache
Operations
Operations
Installing a license key with HP SmartCache
Enabling SmartCache Write-back
Operations
Splitting a mirrored array
Working with mirrored arrays
Recombining a split mirrored array
Creating a split mirror backup
Healing an array
Replacing an array
Setting Auto RAID
Click Create Arrays with RAID
Operations
Managing FLS
Setting
Managing modes
RAID mode or HBA mode
Operations
Power modes
Viewing controller status
Performing a Diagnostics task
Diagnostic tasks
Operations
Opening the CLI in Console mode
Using the HP SSA CLI
\Program Files\hp\hpssacli\Bin\hpssacli.exe
Root@localhost root# hpssacli
Command variable
Opening the CLI in Command mode
CLI syntax
Target variable
Querying a device
Available options are Current value Default
Hiding warning prompts
= ctrl ch=Lab4 ld 1 modify raid=0 ss=?
Target controller show config detail
Show command
Keyword abbreviations
Target show detailstatus
= ctrl all show
= ctrl ch=lab4 show config
Help command
Displaying the current versions of the application layers
Version
Typical procedures
Setting the boot controller
Setting the boot volume
Identifying devices
Setting the target
Set target target
= set target ctrl slot=3 = clear target
Deleting target devices
Generating a diagnostic report
Target modify led=onoff
Target delete forced
Rescanning the system
Erasing a physical drive
Entering or deleting a license key
Optimizing controller performance for video
Target create type=ld parameter=value
Creating a logical drive
Sample scenario
Available options are +0 default value
Moving a logical drive
Target modify newarray=
Target modify drives=# ##,# ##,# ##-# ##
Viewing SSD physical drives
Viewing enclosure information
Viewing SSD information
SmartCache in Hpssacli
SSD Over Provisioning Optimization
Rapid Parity Initialization methods
Assigning a chassis name to the controller
= ctrl slot=1 array B create type=ldcache datald=2
Managing spare drives
Setting the spare activation mode
Target modify spareactivationmode= failure predictive
Controller slot=1 modify spareactivationmode=predictive
Spare Management Mode in Hpssacli
Expanding an array
Shrinking an array
Moving an array
Target remove drives=###-###
Target modify drives=###-### spares=###-###
Extending a logical drive
= ctrl slot=1 create type=arrayr0 drives=allunassigned
Target modify size=#max? forced
Target modify raid=01+0156adg? ss=8163264128256default?
Setting the preferred path mode
Migrating a logical drive
Target modify preferredpathmode=automaticmanual?
Changing the Rebuild Priority setting
Disabling a redundant controller
Assigning a redundant controller to a logical drive
Setting the surface scan mode
Changing the Expand Priority setting
Changing the surface scan delay time
Re-enabling a failed logical drive
Changing the controller cache ratio
Enabling or disabling the drive cache
Enabling or disabling the array accelerator
Using the Split Mirror command
Enabling a script to exit on error
Set exitonerror=enable set eoe=disable Show exitonerror
Enabling SmartCache Write-back
Target modify latency=lowhighdisable?
HBA mode
Controller slot=5 modify latency=low
Target modify hbamode=onoff?
Using HP SSA scripting
Power mode
RAID mode
Using an Input script
Capturing a configuration
Creating an HP SSA script file
Hpssascripting -c Filename -internal -external -e Filename
Sample custom input script
Script file requirements
Date captured Wed Jan 15 153314 Version
Sample custom capture script
Sample encryption script
Initial encryption configuration
PlainText= Enable
Encryption configuration
Script file options
Method mode
Action mode
Control category
Controller category
ClearConfigurationWithDataLoss
Controller
CacheState
ElevatorSortEnable
DPOEnable
IRPEnable
DriveWriteCache
NoBatteryWriteCache
MNPDelay
Power modes
LicenseKey, DeleteLicenseKey
SurfaceScanDelayExtended
SurfaceScanDelay
QueueDepth
RapidParityInitialization
Array category
DPOEnable = No ElevatorSortEnable = Yes IRPEnable = No
Array
ArrayR0
Drive
CachingArray
DriveType
OnlineSpareMode
Logical Drive category
OnlineSpare
SplitMirror
ArrayAccelerator
LogicalDrive
CachingLogicalDrive
CachedLogicalDrive
NumberOfParityGroups
PreferredPath
SetBootVolumeSecondary
SetBootVolumePrimary
Renumber
Repeat
SizeBlocks
Size
SmartCache Write-back
StripSize
Encryption controller category
Encryption support commands
Remove Suspend Resume
ControllerPasswordMode
EncryptionRecoveryQuestion
Encryption logical volume category
XML support
XML output
\hpssascripting -c out.xml
XML input
XML input file DTD
Comment or clarification Code
HP SSA scripting warning messages
Error code Error message Comment or clarification
HP SSA scripting error messages
This error can occur when you attempt to add or
Or logical drive
Free space for the requested size 3011
Expand array and changed the size or RAID level
ACCEPTEULA=YES
HP Smart Storage Administrator Diagnostics Utility CLI
About the utility
Reported information
Troubleshooting
Field Description
Installing the utility
Launching the utility in CLI mode
Diagnostic report procedures
SmartSSD Wear Gauge report procedures
512e Physical drive support
Drive arrays and fault-tolerance methods
Drive arrays
Identifying and viewing SmartSSD Wear Gauge report files
Troubleshooting
Troubleshooting
Effects of a hard drive failure on logical drives
Fault-tolerance methods
RAID 1 and RAID 1+0 RAID
RAID 0-No fault tolerance
Troubleshooting
RAID 1 ADM and RAID 10 ADM
RAID 5-distributed data guarding
RAID 6 ADG-Advanced Data Guarding
RAID
Comparing the hardware-based RAID methods
Selecting a RAID method
Alternative fault-tolerance methods
Diagnosing array problems
Diagnostic tools
Troubleshooting resources
Troubleshooting
HP Secure Encryption
Optional components
About Saap
HP Smart Array Advanced Pack
ILO
Acronyms and abbreviations
PXE
Documentation feedback
Index
HP Smart Storage Administrator Diagnostics Utility
XML DTD
Top
Page
Image
Contents