<!ATTLIST Array ID PCDATA #REQUIRED > <!ELEMENT Drive ( ALL #PCDATA ) > <!ELEMENT OnlineSpare ( YES NO #PCDATA ) >

<!ELEMENT LogicalDrive ( Raid, Repeat Size, Sectors, StripeSize, ArrayAccelerator? ) >

<!ATTLIST LogicalDrive ID PCDATA #REQUIRED ><!ELEMENT ArrayAccelerator ( ENABLE DISABLE ) ENABLE ><!ELEMENT Raid (0 1 1ADM 10 10ADM 4 5 6 ADG 50 60)

>

<!ELEMENT Repeat ( MAX #PCDATA ) > <!ELEMENT Sectors ( 32 63 ) > <!ELEMENT Size ( MAX #PCDATA ) MAX >

<!ELEMENT StripeSize ( 8 16 32 64 128 256 512 ) >

]>

HP SSA scripting warning messages

WarningWarning messageComment or clarification

 

code

 

 

 

 

 

 

 

4000

License key is already installed

The input file specified a license key. However, a

 

 

 

license key is already installed on the controller.

 

4001

Clear configuration command failed -

The -resetoption was used on a controller that

 

 

configuration is already cleared

does not have a configuration.

 

4002

Chassis name is already set to this value

The chassis name is already set to the supplied

 

 

 

value. The command is ignored.

 

4003

One or more controller commands were

Certain commands require that the controller be

 

 

skipped because the controller is not

configured before they can be sent to the controller.

 

 

configured

 

 

4004

Using Repeat function

Some commands have been ignored because the

 

 

 

Repeat parameter has been specified in the input

 

 

 

file.

 

 

 

 

 

4005

The system must be rebooted for the firmware

A controller has been flashed with new firmware.

 

 

flash to complete

The new firmware requires a reboot to take effect.

 

4006

Unable to set the array accelerator for this

The controller may not support a cache (for

 

 

volume. The cache board may be missing or

example, some Software RAID controllers) or the

 

 

have a bad status, or the controller may not

cache may be missing or defective.

 

 

support a cache

 

 

4007

The controller does not have a battery

The operation requested requires a battery and one

 

 

attached

was not attached.

 

4008

The controller battery status is Failed

The operation requires a battery and the attached

 

 

 

battery has failed.

 

4009

This parameter cannot be modified

The input script attempted to modify a parameter

 

 

 

which is not modifiable.

 

4010

Rapid Parity Initialization is not available

Rapid Parity Initialization is not available on the

 

 

 

selected volume; there may already be an RPI in

 

 

 

progress, or the firmware does not support RPI.

 

 

 

 

 

4011

The command is not available when

 

 

MODE=CONFIG

 

 

 

 

Operations 105