<!ATTLIST Array ID PCDATA #REQUIRED > <!ELEMENT Drive ( ALL #PCDATA ) > <!ELEMENT OnlineSpare ( YES NO #PCDATA ) >
<!ELEMENT LogicalDrive ( Raid, Repeat Size, Sectors, StripeSize, ArrayAccelerator? ) >
<!ATTLIST LogicalDrive ID PCDATA #REQUIRED >
<!ELEMENT ArrayAccelerator ( ENABLE DISABLE ) ENABLE >
<!ELEMENT Raid (0 1 1ADM 10 10ADM 4 5 6 ADG 50 60)
>
<!ELEMENT Repeat ( MAX #PCDATA ) > <!ELEMENT Sectors ( 32 63 ) > <!ELEMENT Size ( MAX #PCDATA ) MAX >
<!ELEMENT StripeSize ( 8 16 32 64 128 256 512 ) >
]>
HP SSA scripting warning messages
Warning | Warning message | Comment or clarification |
|
code |
|
|
|
|
|
|
|
4000 | License key is already installed | The input file specified a license key. However, a |
|
|
| license key is already installed on the controller. |
|
4001 | Clear configuration command failed - | The |
|
| configuration is already cleared | does not have a configuration. |
|
4002 | Chassis name is already set to this value | The chassis name is already set to the supplied |
|
|
| value. The command is ignored. |
|
4003 | One or more controller commands were | Certain commands require that the controller be |
|
| skipped because the controller is not | configured before they can be sent to the controller. |
|
| configured |
|
|
4004 | Using Repeat function | Some commands have been ignored because the |
|
|
| Repeat parameter has been specified in the input |
|
|
| file. |
|
|
|
|
|
4005 | The system must be rebooted for the firmware | A controller has been flashed with new firmware. |
|
| flash to complete | The new firmware requires a reboot to take effect. |
|
4006 | Unable to set the array accelerator for this | The controller may not support a cache (for |
|
| volume. The cache board may be missing or | example, some Software RAID controllers) or the |
|
| have a bad status, or the controller may not | cache may be missing or defective. |
|
| support a cache |
|
|
4007 | The controller does not have a battery | The operation requested requires a battery and one |
|
| attached | was not attached. |
|
4008 | The controller battery status is Failed | The operation requires a battery and the attached |
|
|
| battery has failed. |
|
4009 | This parameter cannot be modified | The input script attempted to modify a parameter |
|
|
| which is not modifiable. |
|
4010 | Rapid Parity Initialization is not available | Rapid Parity Initialization is not available on the |
|
|
| selected volume; there may already be an RPI in |
|
|
| progress, or the firmware does not support RPI. |
|
|
|
|
|
4011 | The command is not available when | — |
|
| MODE=CONFIG |
|
|
|
| Operations 105 |