Script file options

Options in HP SSA script files are divided into the following categories:Control category (on page 87)Controller category (on page 87)Array category (on page 92)Logical Drive category (on page 94)

Each category has several scripting options, but you do not always need to assign values to every option. HP SSA can use default values in some instances, while in other instances, a listed option might not be relevant for a particular configuration or scripting mode.

The options for each category are listed in the following table and described in more detail in the remainder of this section.

CategoryOptions

Description

 

 

 

Control

Action

These options define the overall behavior of HP SSA

 

Method

when it processes scripts and creates configurations.

 

 

Control options can occur only once in a script file and

 

 

must be listed first.

 

 

 

Controller

Controller

Options in this category specify the controller that is to be

 

CacheState

configured (or the controller that had its configuration

 

ClearConfigurationWithDataLoss

captured). Although the Controller option must begin this

 

DeleteLicenseKey

section of the script, you can script other options in this

 

DPOEnable

category in any order.

 

DriveWriteCache

You can use one script file to configure all controllers in a

 

ElevatorSortEnable

system, and you can configure the controllers identically

 

ExpandPriority

or individually. If you define each controller configuration

 

IRPEnable

individually, enter the option values for one controller

 

LicenseKey

and its arrays and logical drives before specifying the

 

MNPDelay

option values for another controller.

 

NoBatteryWriteCache

 

 

PreferredPathMode

 

 

QueueDepth

 

 

RaidArrayId

 

 

ReadCache

 

 

RebuildPriority

 

 

SurfaceScanDelay

 

 

SurfaceScanDelayExtended

 

 

SurfaceScanMode

 

 

WriteCache

 

Array

Array

These options describe an array that is to be configured

 

Drive

on the controller that was previously specified in the

 

DriveType

script. (If no controller was previously specified, HP SSA

 

Join

stops processing the script and creates an error file.)

 

OnlineSpare

Although the Array option must begin this section of the

 

Split

script, you can script the other options in this category in

 

 

any order.

 

 

 

Operations 86