ArrayAccelerator (on page 95)

LogicalDrive (on page 95)

CachingLogicalDrive (on page 95)

CachedLogicalDrive (on page 96)

NumberOfParityGroups (on page 96)

PreferredPath (on page 96)

RAID (on page 96)

Renumber (on page 97)

Repeat (on page 97)

SetBootVolumePrimary (on page 97)

SetBootVolumeSecondary (on page 97)

Sectors (on page 97)

Size (on page 98)

SizeBlocks (on page 98)

SmartCache Write-back (on page 98)

SSDOPO (on page 98)

StripSize (on page 98)

ArrayAccelerator

This option specifies whether the array accelerator is enabled or disabled for the specified logical drive. The default value is Enabled.

LogicalDrive

The value that you enter for this option specifies the ID number of the logical drive that is to be created or modified. The first logical drive on an array must have an ID of 1 (not 0), and logical drive numbering must be contiguous.

In Configure action mode, HP SSA accepts only the ID number of the next possible logical drive.

In Reconfigure action mode, HP SSA also accepts the ID number of any existing logical drive.

CachingLogicalDrive

The value that you enter for this option specifies the ID number of the caching logical drive that is to be created or modified. The first logical drive on an array must have an ID of 1 (not 0), and logical drive numbering must be contiguous.

In Configure mode, HP SSA accepts only the ID number of the next possible logical drive.

In Reconfigure mode, HP SSA also accepts the ID number of any existing logical drive. Caching logical drives and cached data drives must be on the same Array Controller.

Operations 95