7 • Maintenance
Maintaining the Moistener (DM400c Only) Continued.
Cleaning the Shield and Wick
1.Open the feeder cover and remove the moistener bottle. Leave the moistener bottle out until instructed to replace it.
2.Remove the stripper blade and brush assembly.
3.Pull the moistener tank straight out towards you. Gently lift the tank up and out.
IMPORTANT: The moistener tank may be full of sealing solution. If so, you can pour the solution back into the moistener bottle, or drain the tank into a receptacle.
4.Pull up and remove the shield and wick from the moistener tank.
5.Separate wick from the shield. Clean the wick in plain water, and rinse thoroughly.
NOTE: If the wick and shield cannot be cleaned thoroughly, they will need to be replaced.
6.Place the wick back into the shield.
Shield
Wick
7.Push the wick and shield back into moistener tank.
8.Slide the tank back in place.
9.Replace the stripper blade and brush assembly by pushing up on the release lever and sliding the assembly back on it's track until it snaps into position.
10.Replace the moistener bottle and close the feeder cover.