Item Description Min. Max. Units
1 HS low time 2 200 VCLK periods
2 HS to VCLK phase difference 10 VCLK period - 10 nsec
3 HS to DE phase difference 2 HS period - 340 VCLK periods
4 DE set up time 5 VCLK period - 10 nsec
5 VCLK frequency 7 MHz
6 R/G data set up to VCLK 5 nsec
7 R/G data hold from VCLK 10 nsec
8 VS low width 2 34 HS periods
9 VS to HS phase difference 0 HS period – HS low
time
nsec
10 Vertical start position After 7 HS rising edges
DE high time 2 HS period - 10 VCLK periods
HS period 50 usec
VS period 251 280 HS periods