EL552.256-Q2

Environmental

Table 6. Environmental Specifications

 

Operating

Non-operating

Temperature*

0 to +65 °C

-40 °C to +75 °C

Humidity

 

 

Non-condensing

to 93% RH max @40 ºC,

 

 

per IEC 68-2-3

 

 

 

 

Altitude

 

 

Tested per IEC 68-2-13

16,000 ft. (4.8 km)

58,000 ft. (17.7 km)

 

 

 

Vibration (random)

 

 

(Operating/non-

0.02 g2/Hz at 20-500 Hz for 30 minutes on each

operating)

axis, per IEC 68-2-36, test Fdb.

 

 

 

Mechanical Shock

 

 

Operating/non-operating

50 g with 11 ms duration, half sine wave, 3

 

shocks on each of 6 surfaces, per IEC 68-2-27,

 

test Ea.

 

 

 

 

*The EL display will function at operating survival temperatures (-20 to +70 °C) for a 24-hour period and incur no damage, but may not meet some specifications above the +65°C operating limit.

Reliability

The display mean time between failure (MTBF) is demonstrated to be greater than 30,000 hours at 25 °C ambient with a 90% confidence level.

Safety and EMI Performance

The display will not inhibit the end product from obtaining UL1950, CSA950, or IEC 601-1 safety certification.

When housed in a suitable enclosure, the display is capable of being operated in a final product that complies with CISPR 11 level B, IEC 801-2 (ESD), and IEC 801-3 (EMI susceptibility).