Remote Control

Key Pad function

Menu Key function

Power Key function

5V

12V

Ambient Sensor

Thermal Sensor

Operating Time

8

8

8

9

9 A

 

 

g

 

68

000: Disable

 

 

 

 

001: Enable

 

 

 

 

 

 

 

 

 

 

002: Pass

 

 

 

 

 

through

 

 

 

 

69

000: Disable

 

 

 

 

 

001: Enable

 

 

 

 

73

000: Disable

 

 

 

 

 

001: Enable

 

 

g

 

74

000: Disable

 

 

 

 

 

001: Enable

 

g

 

m

6D

000~50

 

g

 

n

6E

000~120

 

g

 

p

70

0000 ~ 2000

 

g

 

q

71

-055 ~ +125

 

g

 

v

76

0 ~ 65535

 

 

 

 

 

 

Lock

Lock

Lock

Lock

Hour

4Protocol 2 : without ID

4.1Set function listing

The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 5 bytes. Note that the “Value” byte is always = 00.

Set-Function description:

Length:

Total bytes of message = 5 ASCII (35H) excluding “CR”

Command:

Function command code: One byte ASCII code

Value[1~3]:

Three bytes ASCII that defines the value

Set-Function format:

Name

Length

Byte Count

1 Byte

Bytes order

 

1

Command

1Byte 2

Value1

1Byte 3

Value2

1Byte 4

Value3

1Byte 5

CR

1Byte 6

All Set-Function from PC to Monitor (ASCII)

 

Name

Length

Command

Value1

 

Byte Count

 

1 Byte

1 Byte

 

5

 

Bytes order

 

2

3

 

1

Example: Set Mute-ON command (ASCII)

 

Name

Length

Command

Value1

 

Byte Count

 

6

0

 

5

 

Bytes order

 

2

3

 

1

Value2

1Byte 4

Value2

0

4

Value3

1Byte 5

Value3

0

5

CR

00D

6

CR

00D

6