Planar PS5551, PS5550, PS6500, PS4200TL, PS4250, PS4650 manual 1Introduction

Models: PS4650 PS4200TL PS4200 PS6500 PS4250 PS5551 PS5550

1 21
Download 21 pages 9.58 Kb
Page 2
Image 2
1Introduction

1Introduction

This document describes the hardware interface spec and software protocols of RS232 interface communication between Commercial Display and PC or other control unit with RS232 protocol.

1.Protocol 1, with ID

This set protocol allow user to assign the ID in the command to control the specify ID monitor

2.Protocol 2, without ID

The set protocol is best for single display control

Both sets protocol contain three sections command:

￿Set-Function

￿Get-Function

￿Remote control pass-through mode

In below document, “PC” will represents all the control units that can sent or receive the RS232 protocol command.

2Description

2.1Hardware specification

LCD communication port in the rear side

(1)Connector type: DSUB 9 Pin Male

(2)Pin Assignment

 

Pin #

Signal

Remark

Male DSUB 9Pin

1

NC

 

(outside view)

2

RXD

Input to LCD

 

 

 

Monitor

 

3

TXD

Output from LCD

 

 

 

Monitor

 

4

NC

 

 

5

GND

 

 

6

NC

 

 

7

NC

 

 

8

NC

 

 

9

NC

 

 

frame

GND

 

*Use of crossover (null modem) cable required for use with PC

2.2Communication Setting

- Baud Rate Select:

9600bps (fixed)

- Data bits:

8bits (fixed)

- Parity:

None (fixed)

- Stop Bits:

1(fixed)

2.3Command Message Reference