Environmental Conditions for Installation

Environmental Conditions for Installation

Environmental Conditions for Installation

Since the PS5580 panel is very sensitive to physical impact, installation requires considerable caution

Minimum clearance (20 mm) must be observed—top, bottom, and both sides—for proper ventilation. Installation must avoid air-tight or nearly air-tight places. Improper ventilation causes malfunction and shortens product life by a rapid internal temperature rise. If the PS5580 must be installed with improper ventilation, additional ventilation openings or fans must be provided to keep the internal temperature between 0°-35°C (32°-95°F).

For grounding the PS5580 and attached devices, it should be connected as a frame ground.

Considering the PS5580 max power consumption, check the main electrical specification.

Regularly clean the vent holes in the back of the PS5580 to prevent overheating.

Recommended Operating Conditions

Temperature: 5-35°C (41-95°F)

Humidity 35-75%

Do not install the set it an air-tight condition; provide adequate ventilation.

Do not install the set in a place of direct sunlight or excessive exposure to lights.

WARNING Blackening, stains or burning effect on the screen may occur through improper installation or use outside these recommended conditions.