Polycom KWS8000 manual Rack mounting Safety Precautions

Models: KWS8000

1 38
Download 38 pages 61.5 Kb
Page 6
Image 6
Rack mounting Safety Precautions.

KWS8000 Installation

Rack mounting Safety Precautions.

Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.

In a single rack installation, stabilizers should be attached to the rack.

In multiple rack installations, the racks should be coupled together.

Always make sure the rack is stable before extending a component from the rack.

You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable.

Before you install the rails, determine the placement of each component in the rack.

Install the heaviest components on the bottom of the rack first, and then work up.

Always keep the rack’s trays and board’s closed when not servicing, to maintain proper cooling.

The rack ambient temperature may rise beyond room ambient temperature in a multi unit assembly, measures must be taken to ensure the KWS8000 ambient temperature does not exceed the maximum operating ambient temperature of 40 °Celsius.

To ensure ventilation always leave 2/3 U between the KWS8000 units any other units mounted in the rack.

Always ensure proper rack earthing.

To Install the KWS8000 in a Rack

You can install the KWS8000 in a rack using one of the two following methods:

>>Install the brackets supplied by the rack manufacturer on each side of the rack on which the KWS 8000 is placed. Secure the system by fastening four screws to the rack on the front panel.

>>Install a shelf supplied by the rack manufacturer on top of which the KWS8000 is placed. Secure the system by fastening four screws to the rack on the front panel.

1–3

Page 6
Image 6
Polycom KWS8000 manual Rack mounting Safety Precautions