Chapter 2- Component Replacement
2-8
4Using a star screw driver, disconnect the two wires connected to the
Terminal block (-48V IN & -48V RTN) of the failed DC PRM unit.
5Unscrew the captive screws on the rear panel of the PRM unit that
secures the unit to the chassis.
6Using the handle fitted to the DC PRM, pull and slide the PRM unit
out.
7Slide in the replacement PRM unit.
8Push the PRM unit firmly into the chassis, making sure it is properly
seated in its slot.
9Tighten the captive screws on the rear panel of the PRM unit to the
rear chassis.
10 Connect the black wire into the -48V IN terminal block and the red
wire to the -48V RTN terminal block and tighten the two screws.
11 Turn ON the Main that supplies power to the RMX.
12 Turn ON the circuit breaker on each of the DC Power Rail Modules.