Set the Switch Interface Type

Interface Implementation

See the documentation for your SpectraLink components for more information about wiring the demarc block or patch panel.

The following table shows the patch cord pinout for the Avaya side of the modular 8-pin (RJ45) connector.

Pin

Function

1

Receive

 

 

2

Receive

3

Transmit

6

Transmit

 

 

Each digital pair is polarity insensitive. If you reverse polarity the system will still work.

Set the Switch Interface Type

SpectraLink 6100 MCU

The SpectraLink 6100 Master Control Unit (MCU) requires the switch interface type to be configured using the front panel buttons. The configuration procedures are detailed in the SpectraLink 6100 MCU: Installation and Operation document.

SpectraLink 6300 MCU

When configuring the SpectraLink 6300 MCU, the PBX interfaces are available as sub-menu selections when defining the Interface Module type using the SpectraLink 6300 MCU Operator’s Console. Refer to the SpectraLink 6300 MCU: Operator’s Console document for details on configuring the Interface Modules.

SpectraLink 8000 Telephony Gateways

Connect to the SpectraLink 8000 Telephony Gateway using the serial or modem interface. From the Main Menu, choose Gateway Configuration. Scroll to Telephone Switch Type and press enter to change this field, from the Submenu of PBX types, select DEFINITY. Refer to the SpectraLink 8000 Telephony Gateway: Administration Guide for SRP document for details on configuring the Telephone Switch Type.

PN: 1725-36130-001_E.doc