wise).

7.Replace hose and new hose clamp.

8.Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.

TO REPLACE REGULATOR

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug unit.

3.Using an adjustable wrench remove the gauges, quick connect, and safety valve from the regulator manifold.

4.Remove the hose by removing the hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see the Parts List Manual or purchase a standard hose clamp at a local hardware store.

Safety Gauges

Valve

Regulator

Quick Connect

Manifold

 

 

5.Remove pump mounting screws securing pump (one on each side).

6.Carefully slide pump from brackets and out of the way.

7.Using an adjustable wrench remove the regulator manifold.

8.Apply pipe sealant to new regulator manifold and assemble, tighten with wrench.

9.Reapply pipe sealant to gauges, quick connect, and safety valve.

10.Reassemble all components in reverse order of removal. Make sure to orient gauges to read correctly and use wrenches to tighten all components.

Hose

 

Pump Mounting Screw

Clamp

 

 

 

 

 

Regulator

Manifold

Pump shown moved out of the way

Regulator

Manifold

15 - ENG

1000003754

Page 15
Image 15
Porter-Cable 1000003754 instruction manual To Replace Regulator